Capture Inrush, Micro and High-Speed Currents with a Single Probe
Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The CT6710 is a 3-range, high-sensitivity current probe that offers a wide DC to 50 MHz bandwidth and 200 μA to 30 A input, letting your capture signals across an expansive current range, from steady state to transient currents, when developing switching power supplies, inverters, and motor controllers.
Use with an instrument with a high input impedance of 1 MΩ or higher.
CT6710 | From 200μA, 50MHz bandwidth |
---|
Monitor current under a broad range of operating conditions from 0.5 to 30A. Simply press the RANGE key on the termination box to toggle between ranges, and analyze everything from sudden inrush to slow moving consumption current, down to micro currents of low energy devices, all with a single device.
When input exceeds the rated value, a warning indicator flashes to signal a warning. In addition, if you select the incorrect range and then input a current signal that is above the rated current for that range, this function protects the instrument from damage due to overheating. Caution: Input currents that exceed the frequency derating for the 30 A range may cause measurement circuit damage before the protection function kicks in.
Observe waveforms as they are without needing to rely on your oscilloscope’s filter settings and averaging function. The 10V/A output rate is 10 times the traditional 1V/A rate of legacy products, allowing you to improve the oscilloscope’s voltage sensitivity by a factor of 10, thereby enhancing the S/N ratio of the scope itself to deliver much clearer waveforms.
Frequency bandwidth | DC to 50 MHz (-3 dB) | |||||
---|---|---|---|---|---|---|
Rise time | 7.0 ns or shorter | |||||
Delay time (Typical) |
30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns (Delay time relative to rising waveform of input signal 1 ns) |
|||||
Noise level | 75 μA rms max (at 0.5 A range, using 20 MHz band measuring instrument) | |||||
Max. rated current | 30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms (DC, and sine wave, requires derating at frequency) |
|||||
Max. allowable peak current | 30 A range: ±50 A peak (within the input limit time 2 s) 5 A range: ± 7.5 A peak, 0.5 A range: ± 0.75 A peak (< 10 MHz), ±0.3 A peak (≥ 10 MHz) |
|||||
Amplitude accuracy | 30 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (≤ 10 Arms, DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) 5 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) 0.5 A range: ±3.0% rdg. ±10 mV, (Typical) ±1.0% rdg. ±10 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range) |
|||||
Output rate | 30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A, (The output of this probe is internally terminated) | |||||
Measurable conductors | φ 5 mm (0.20 in), Insulated conductor | |||||
Power supply | Supplied from Power Supply 3269, Probe Power Unit Z5021 | |||||
Cable length | Sensor cable (between relay box and sensor): 1.5 m (4.92 ft) Power cable: 1.0 m (3.28 ft) (Power plug: FFA.0S.304.CLAC37Y / LEMO inc.) |
|||||
Dimensions and mass | Sensor: 155 mm (6.10 in)W × 18 mm (0.71 in)H × 26 mm (1.02 in)D, Relay box section: 45 mm (1.77 in)W × 120 mm (4.72 in)H × 25 mm (0.98 in)D Terminator section: 29 mm (1.14 in)W × 83 mm (3.27 in)H × 40 mm (1.57 in)D mm, 370 g (13.1 oz) |
|||||
Included accessories | Instruction manual ×1, Carrying case ×1 |