Sensor information PCE-AC420-210
- Range Measuring 0.2 ... 20 mm / s
- Linear frequency range (± 3 dB) 10 ... 1000 Hz
- Degree of protection IP67
- Shielded connector 713 (M12), axial
- Approx. 66 g
Technical Specifications - PCE-AC420-210 Sensor | |
Measuring range (RMS) at 4-25-mA | 0.2 ... 25 mm / s |
Nominal value (RMS) at 20-mA | 20 mm / s |
Sensitivity | 0.8-mA / mms-1 |
3 dB lower frequency limit | 10 Hz |
3 dB upper frequency limit | 1000 Hz |
Stabilization time at 1% tolerance | 2 s |
Loop supply voltage | 12 ... 30V |
Destruction limit | ± 4000 g / 8.8 lbs |
Transverse sensitivity | <5% |
Operating temperature | -40 ... 85ºC / -40 ... 185ºF |
Type of protection | IP67 |
Weight without cable | 66 g / 2.3 oz |
Shell material | Stainless steel |
Connector | Male connector |
Mounting | M8 threaded hole |
Technical specifications - PCE-DPD-U screen | |
Screen | 4-digit red LED |
Digit Height | 14 mm |
Processes | Vexc +15 Vdc configurable in terminal 5 |
Response time | < 300 mSec (0% to 99% signal) |
'U' power | 18 to 265V AC / DC (isolated 1500 Veff @ 60 sec.) |
Power | 230V AC / 24V (depending on version) |
Entry | 4 ... 20-mA |
Departures | SLOT1: relay R1 included (optionally, you can request analog output 4-20..A or RS485 Modbus RTU output) SLOT2: empty (optionally, you can request a relay relay R2, if R1 is already installed) |
Type of protection | IP65 |
Connections | Screw plug-in terminal |
Feeding | 18… 265V AC (50 / 60Hz) / DC |
Environmental conditions | 0 ... 50°C / 32 ... 122°F |
Weight | < 150 grams |
Dimensions | 96 x 48 x 91 mm / 3.8 x 1.9 x 3.6 in (including terminal) |
General specifications | |
Regulations | To control machinery for predictive maintenance according to ISO2372, ISO10816, ISO20816, etc. |
Alarm | Configurable setpoint |