021 -2216 3350
info@bapj.co.id

Amprobe VPC-12 Voltage and Countinuity Tester

Update Terakhir
15 Oktober 2021
Negara Asal
Amerika
Pembelian minimum
1
Harga
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

Specification of Amprobe VPC-12 Voltage and Continuity Tester
Spesifikasi Amprobe VPC-12 Voltage and Continuity Tester
Amprobe VPC-12 Voltage and Continuity Tester

 

Features

  • LEDVoltage range

24…600 VAC, 6…220 V DC

  • LEDvoltage indicators

AC volts:24 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V,

DC volts: 6 V, 12 V, 24 V, 36 V, 48 V, 110V, 220 V

  • Frequencyrange

50 to 60Hz

  • Acousticindication

≥ 24 VAC,≥ 6 V DC

  • Built-invibration alert

≥ 24 VAC,≥ 6 V DC

  • TolerancesLEDs

-30% to 0%of reading

  • Voltagedetection

Automatic

  • Hazardousvoltage indication

≥ 24 VAC;≥ 48 VDC

  • Rangedetection

Automatic

  • Polaritydetection

Full range

  • Continuityindication

LED,buzzer and vibration ( 0 to 45 kΩ ON; >85 kΩ OFF)

  • Continuityrange

0 to 45 kΩ

  • Continuitytolerances

0% to +50%

  • Continuitybuzzer

3 kHz

  • VolTect™non-contact voltage

90 to 600VAC, Sensitivity: beeps and vibrates ≤ 10 mm (0.39 in)
distance from a wire carrying 100 VAC

  • Work light

yes

  • Inputimpedance

1 MΩ

  • Operatingtime

30 secondsON maximum and wait for five minutes

before taking another measurement

  • Operatingaltitude

≤ 6561 ft(2000 m)

  • Operatingtemperature

41 °F to122 °F (5 °C to 50 °C)

  • Storageconditions

-22 °F to140 °F (-30 °C to 60 °C)

  • Humidity(Without Condensation)

≥ 80% RHat 41 °F to 104 °F (5 °C to 40 °C);

≥ 50% RHat > 104 °F to 122 °F (> 40 °C to 50 °C)

  • Pollutiondegree

2

  • Powersupply

Three 1.5V battery AAA, LR03, UM4 or equivalent

  • Batterylife

40 hours(alkaline) (typical)

  • Electricalsafety

CAN/CSA-C22.2No. 61010-1-12, UL Std. No. 61010-1 (3rd Edition),
CAN/CSA-C22.2 No. 61010-031-07, UL 61010-031 (1st Edition – 2007),
CAN/CSA-C22.2 No. 61010-2-030-12, UL 61010-2-030(1st Edition -2012)

  • Overvoltagecategory

CAT IV 600V
In CAT III or CAT IV environments, use the test probes

with theprobe cap on.

Thisdecreases the exposed probe tip to reduce the possibility of arc flash fromshort circuits.

When theprobe cap is off, the probe tip is 18 mm and rated to CAT II 1000 V.

  • EMC

Conformsto IEC 61326-1

  • Dimensions(H x W x D)

5.90 x2.13 x 1.34 in (150 x 54 x 34 mm)

  • Weight

Approximately0.45 lb (205 g) with batteries installed