In addition to being used in the process (to power a remote display or a regulator) as fixed or wall-mounted units, the differential pressure transducers can also be used as an on-site meter or even mobile. The optional LCD display allows on-site reading. With the help of the automatic zero setting, the measuring devices can be quickly reset on site. The analogue output can also be used in combination with the optional datalogger offered by us in the accessories. This allows you to record the differential pressure readings over a longer period of time, later transfer the stored data to a computer and analyze it there.
| Measuring ranges | Adjustable by the user | Max. static pressure |
| 1.6 mBar 4.0 mBar 10 mBar 40 mBar 250 mBar 10000 mBar ± 1.6 mBar |
1.0 mBar 2.5 mBar 6 mbar 25 mbar 60/160 mbar 400/600 mbar |
200 mbar 200 mbar 200 mbar 345 mbar 1000 mbar 3000 mbar 200 mbar |
| Media | Gases Air |
|
| Exit | 3-wire switchable: 0 ... 10 V / 0 ... 20 mA 0 ... 5 V / 4 ... 20 mA 2-wire: |
|
| Response time | <100 ms Damping adjustable via potentiometer 0 ... 5000 ms |
|
| Long-term stability | ≤ ± 1% FSO / year PN <6 mbar ≤ ± 0.5% FSO / year for PN ≥ 6 mbar |
|
| Measuring rate | 12.5 Hz | |
| Switching output | For 3-wire version: 2 x 230V / 2A change-over relays For 2- |
|
| Temperature error | ≤ ± 0.5% FSO / 10 K (typ.) For PN <6 mbar ≤ ± 0.3% FSO / 10 K (typ.) For PN ≥ 6 mbar |
|
| Operating conditions | Medium: 0 ... 50°C / 32 ... 122°F Environment: 0 ... 50°C / 32 ... 122°F |
|
| Storage conditions | -10 ... 70°C / 14 ... 158°F | |
| Short circuit resistance | Permanent | |
| Reverse polarity protection | No damage but no function | |
| EMC | EMC Directive: 2014/30 / EU Emitted interference and Immunity to EN 61326 |
|
| Pressure connection Standard Optional |
Brass Ø 6.6 x 11 (for flexible hoses with Ø 6) Ø 4.4 x 10 (for flexible hoses with Ø 4) |
|
| Casing | SECTION | |
| Sensor | Ceramic, silicon | |
| Media contacting parts | Pressure connection, PVC / silicone, sensor | |
| Display (optional) | 2-line LC display Display accuracy : 0.1% + 1 digit |
|
| Additional functions with display | - Parameterization of the switching outputs - Selection of the unit - Selection of the transfer characteristic (linear, radiated) - Cut-off function (radiated output signal) - Min./max . Value display - Recalibration - Autozero function - Factory setting |
|
| Power supply | 3 conductors: 19 ... 32V 2 conductors: 11 .. 32VWith automatic zeroing: 24 ... 32V |
|
| Current consumption | 3-wire: 30-mA
2-wire: 22-mA |
|
| Weight | About 200 g / < 1 lb | |
| Protection | IP 54 | |