DESCRIPTION

IoT Meter for top hat rail mounting / Measuring range 0 ... 600 V AC/DC /
Output signals in 4 ... 20 mA and 0 ... 10 V / Configurable via keypad /
 Current measuring range 0 ... 5 A AC/DC / Frequency measurement

The IoT meter has an adjustable measuring range of 0… 600 V AC/DC and can therefore measure a wide variety of voltages. For example, it is possible to connect the IoT meter to the supply line in order to monitor the applied voltage. In addition to voltage measurement, the IoT meter can also measure the current directly with a maximum adjustable measuring range of 0 … 5 A AC/DC. A current transformer can be connected to the IoT meter to expand the current range. The measured value is then converted by the IoT meter into a standardized analog 4 … 20 mA or 0 … 10 V signal. Thus the IoT meter is the ideal extension of a process control.

Since the input and output range can be set identically, the transmitter can be used for galvanic decoupling. The transmitter is configured directly via the keypad. This means that no additional cable or software is required for the settings of the signal converter. The transmitter is mounted on a DIN rail. The transmitter is operated with a voltage of 18 … 265 V AC/DC at a frequency of 45 … 65 Hz.

HIGHLIGHTS

- DIN rail mounting
- Measuring range 0 ... 600 V AC/DC
- Active and passive output signal
- Display and keypad for configuration
- Frequency measurement
- Measuring range 0 ... 5 A AC/DC

SPECIFICATION

Input signals
AC voltage
Adjustable measuring ranges 0 ... 1 / 2 / 10 / 15 / 30 / 60 / 100 /
150 / 300 / 450 / 600 V AC,
0 ... 50 / 60 / 75 / 100 / 150 /
200 / 300 / 500 mV AC
Accuracy <0.3 % of full range
Maximum input signal 800 V AC for the measuring ranges 10 ... 600 V AC,
50 V AC for the measuring ranges 50 mV AC ... 2 V AC
Measuring resistance 13 MΩ for the measuring ranges 10 ... 600 V AC,
81 KΩ for the measuring ranges 50 mV AC ... 2 V AC
Measurement type True RMS
Protection category CAT-II 300 V AC
DC voltage
Adjustable measuring ranges unipolar 0 ... 1 / 2 / 10 / 15 / 30 / 60 / 100 /
150 / 300 / 450 / 600 V DC,
0 ... 50 / 60 / 75 / 100 / 150 /
 200 / 300 / 500 mV DC
Adjustable measuring ranges bipolar ±1 / ±2 / ±10 / ±15 / ±30 / ±60 / ±100
/ ±150 / ±300 / ±450 / ±600 V DC,
±50 /± 60 / ±75 / ±100 / ±150 /
 ±200 / ±300 / ±500 mV DC
Accuracy <0.2 % of full range
Maximum input signal 800 V DC for the measuring ranges 10 ... 600 V DC,
50 V DC for the measuring ranges 50 mV DC ... 2 V DC
Measuring resistance 13 MΩ for the measuring ranges 10 ... 600 V DC,
81 KΩ for the measuring ranges 50 mV DC ... 2 V DC
Alternating current
Adjustable measuring ranges 0 ... 1 / 2 / 3 / 4 / 5 A AC,
0 ... 5 / 10 / 20 / 50 / 75 / 300 / 500 mA AC
Accuracy <0.3 % of full range
Maximum input signal 7 A AC for the measuring ranges
300 mA AC ... 5 A AC (for a maximum of 7 seconds),
150 mA AC for the measuring ranges
5 mA AC ... 75 mA AC
Measuring resistance 20 mΩ for the measuring ranges 300 mA AC ... 5 A AC,
3.33 Ω for the measuring ranges 5 mA AC ... 75 mA AC
Direct current
Adjustable measuring ranges 0 ... 1 / 2 / 3 / 4 / 5 A DC,
0 ... 5 / 10 / 20 / 50 / 75 / 300 / 500 mA DC
Accuracy <0.2 % of full range
Maximum input signal 7 A DC for the measuring ranges
300 mA DC ... 5 A D (for a maximum of 7 seconds),
150 mA DC for the measuring ranges
5 mA DC ... 75 mA DC
Measuring resistance 20 mΩ for the measuring ranges 300 mA DC ... 5 A DC,
3.33 Ω for the measuring ranges 5 mA DC ... 75 mA DC
Frequency
Adjustable measuring ranges for voltage 0 ... 100 / 45 ... 55 / 55 ... 65 Hz
Adjustable measuring ranges for current 0 ... 100 / 45 ... 55 / 55 ... 65 Hz
Accuracy <0.2 % of full range
Reaction time
AC signals <350 ms typically 0 ... 99 %
DC signals <90 ms typically 0 ... 99 % without filter
<175 ms typically 0 ... 99 % with 50/60 Hz filter
<350 ms typically 0 ... 99 % with 50/60 Hz filter
Output signals
Active current output 4 ... 20 mA minimum 0 mA and maximum <22 mA
Passive current output 4 ... 20 mA maximum 30 V DC
Voltage output 0 ... 10 V DC
minimum 0 V DC and maximum <11 V DC
Load resistance current output maximum <400 Ω
voltage output minimum >1 KΩ
Further specifications
All accuracies relate to an ambient temperature of 25 °C / 77 °F
Thermal drift 150 ppm / °C
Power supply 18 ... 265 V AC/DC isolated
( 20 ... 240 V AC/DC ±10 %)
Frequency 45 ... 65 Hz
Power consumption <1.5 W
Conductor cross-section 1 ... 2.5 mm²
Overvoltage category CAT-II
Isolation 3000 Vrms for 60 seconds
Protection class IP30
Impact protection IK06
Operating conditions 0 ... 50 °C / 32 ... 122 °F, 0 ... 95 % RH, non-condensing
Storage conditions -20 ... 70 °C / -4 ... 158 °F, 0 ... 95 % RH, non-condensing
Warm-up time 15 minutes
Maximum working height 2000 meters / 6561 feet
Mounting standard DIN rail 35 x 7.5 mm / 1.3 x 0.3"
Connection plug-in screw terminal (grid 5.08 mm / 0.2")
Housing material polyamide V0
Dimensions 106 x 108 x 22.5 mm / 4.1 x 4.2 x 0.9"
Weight <150 g / 5.3 oz

DELIVERY SCOPE

1 x IoT Meter PCE-SCI-E
1 x User manual

DOWNLOADS

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?