Order No. 4-4565-01
JAN Code 4582619635430

Features

  • Uses R448 A, an earth-friendly low-GWP refrigerant. (GWP: 1386) - GWP is approximately 65% lower than LTC-450 alpha (GWP: 3920).
  • Compact and slim, it can be installed in many places.
  • Made with durable stainless steel coils.
  • It uses a new HFC refrigerant with zero ozone depletion potential.
  • The wetted part is made of stainless steel, so it has excellent durability and allows pure water to circulate.
  • It has strong cooling capacity and can be used in a wide range of fields.
  • With the use of an external temperature sensor, the temperature of the object can be measured directly.
  • It has an overload protection device, a high-pressure switch, a safety breaker, and a self-diagnostic function.

Spec

  • Temperature range (deg. C): -20 to + 20
  • Temperature control accuracy: +/- 2.0 degrees C (Room temperature 20 degrees C/Circulation maximum/Power supply 100 VAC 50/60 Hz/Setting 5 ~ 20 degrees C/No load)
  • Circulation system: closed system countercirculation
  • Type of solution used: municipal water, pure water, ethylene glycol, etc.
  • Circulation pump (50/60 Hz): Maximum flow rate 12/12 L/min, Maximum head 5.4/6.6 m (Circulation pump performance is when the pump is used alone)
  • Cooling Capacity: 500 W at 10 C (Ambient temperature: 20 degrees C, 50 Hz, no load.)
  • Circulation nozzle outer diameter: 11 mm (adaptable tube inner diameter: 9 mm)
  • Refrigerator: 450 W
  • Liquid tank: phi 180 x H 180 mm approx. 4.5 L
  • Refrigerant: R 448 A
  • Power supply: 100 VAC 50/60 Hz
  • Timer function: 1 minute to 47 hours 59 minutes (1 minute increments)
  • Self-diagnostic function: Upper/Lower temperature anomaly detection/Sensor anomaly/Refrigerator overload relay/Refrigerator protection timer/Power outage detection/Control temperature anomaly/Memory error
  • External input/output: External temperature sensor input terminal/analog output terminal for thermometer (1 ~ 5 VDC) Alarm output terminal (12 VDC to 17 VDC)
  • Size: 218 x 430 x 563 mm
  • Weight: approximately 32 kg
  • *Pure water that can be used has a conductivity of 10 microS/cm or more (low purity).
  • This product is compatible with the Validation Service (IQ/OQ). Please contact us.
  • *Validation service is a service where installation qualification (IQ) and operational performance qualification (OQ) are performed and inspection documents are submitted at the customer's site.




Hubungi:
PT Bopana Arga Prima Jaya
Jalan Jupiter VI Perum Bintang Metropol
Blok A7 No.16 Bekasi Utara 17122
Jawa Barat, Indonesia
Telp : 021-22163350
Hp : 08119762505 / 081285345374
Email : boney@bapj.co.id / tesa@bapj.co.id

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?