Milwaukee MC810US MAX pH/TDS/Temp Monitor

Why Guard when you can Monitor! The Milwaukee MC810 MAX pH/TDS/Temp Monitor lets you monitor your pH/TDS/Temp levels 24/7 automatically.

Comments From Field Testing

"I run this unit 24/7 and have not had any problems for the past two months. I can monitor 24/7, point a camera on it and connect to my phone."

"Easy to calibrate."

"Using this now, far less expensive than what my friends paid ... I recommend this to any serious grower."

Summary

The Milwaukee MC810 MAX pH/TDS/Temperature Monitor is preferred by people looking to continuously track pH and nutrient levels 24/7. Quick to setup and simple to use, this monitor offers simultaneous display of all three main parameters on 3 large, backlit LCD readouts.

Common uses are nutrient tanks, Hydroponics and aquariums. The MC810 MAX comes with a complete mounting kit including a probe holder.

Accuracy

The Milwaukee MAX Monitor offers an accuracy to ± 0.2 pH with two point manual calibration, TDS accuracy of ±2% Full Scale and ±0.5 °F (0.3C) temperature accuracy.

Automation

Just calibrate the parameters and begin to monitor 24/7!

Design features

  • Fast, easy-to-read current results with 3 large digital backlit LCD readouts.
  • External Switch atop the unit converts EC conductivity to TDS (ppm) using 0.5 or 0.7 conversion factor
  • Simple two-point pH calibration  and one-point TDS, for increased accuracy with manual trimmers for easy adjustment
  • Gel-filled, double junction, lab grade pH electrode for low maintenance and high performance
  • Low maintenance fixed TDS probe
  • 6.5’ probe cables for extra flexibility when testing
  • 12 VDC power supply
  • Compact size of only 6.3” x 4.3” x 1.4”
  • Weighs only 1.2 lbs

Use and Care

pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

Reference junction

The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.

You can extend the life of your pH electrode in the following ways.

Storage

The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

Cleaning

Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.

Calibration

The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your MAX pMonitor accurate. Also, calibrate after cleaning or a long period of storage.

 

'

 

'

Catatan:

 

Harap Tanya stok sebelum melakukan pemesanan.

Barang akan dipacking dengan aman dan rapi.

Tidak ada complain yang diterima setelah transaksi selesai.

Tanpan video unboxing, komplain tidak akan diproses.

Terima kasih!

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?