The Detcon MicroSafe 500 and 600 Series gas detectors feature a non-intrusive operator interface. Calibration and programming instructions appear in simple intuitive and sequential script on a 16-character backlit display. The transmitter design incorporates extensive fault diagnostics with each condition conveniently identified on the transmitter display.
The 500 Series comes standard with a linear 4-20 mA output, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault and calibration status.
The 600 Series includes the same features as the 500 with the addition of 3 alarm relays and an RS-485 serial communications port.
Electrical Classification - Explosion proof
| System Specifications | |
|---|---|
| Sensor Type | Matched-pair catalytic bead |
| Sensor Life | 3 to 5 years typical |
| Measurement Range | 0-100% LEL (lower explosive limit) |
| Accuracy/Repeatability | ±3% 0-50% LEL ±5% 50-100% LEL |
| Response/Clearing Time | T50 <10 seconds; T90 <30 seconds |
| Zero Drift | <5% per year |
| Outputs | Linear 4-20 mA DC HART (optional) |
| Electrical Classification | Explosion proof CSAus Class I, Division 1, Groups C, D (Tamb = -25°C to +40°C) Class I, Zone 1, Group IIB cCSA Class I, Division 1, Groups C, D (Tamb = -40°C to +40°C) Class I, Zone 1, Group IIB |
| Performance Approvals | CSA C22.2 #152-M1984, ISA 12.13.01-2003 |
| Safety Approvals | cCSAus |
| Ingress Protection | NEMA 4X, IP66 |
| Warranty | Sensor: 2 year warranty Transmitter: 2 year warranty |
| Operating Temperature Range | -40°C to +40°C; -40°F to 104°F (CANADA) -25°C to +40°C; -13°F to 104°F (USA) |
| Storage Temperature Range | -40°C to +75°C; -40°F to +167°F |
| Operating Humidity Range | 5-100% RH non-condensing |
| Operating Pressure Range | Atmospheric ±10% |
| Dimensions | 10”H (including splashguard) x 6.1”W x 4.3”D 254mmH x 155mmW x 109mmD Mounting holes (J-box) 5.5”; 140mm center to center |
| Weight | 6 lbs; 2.72kg (w/aluminum j-box) 9 lbs; 4.08kg (w/stainless steel j-box) |
| Power Input | 12-28 VDC |
| Power Consumption | Normal operation = 68mA (<1.7 watt) Maximum = 87mA (2 watts) |
| RFI/EMI Protection | Complies with ISO 92.0.01 |
| Analog Output | Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC) 0mA All Fault Diagnostics 2mA In-Calibration 4-20mA 0-100% full-scale 22mA Over-range condition |
| Status Indicators | 4-digital LED display with gas concentration Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting 4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration |
| Faults Monitored | Loop, Input Voltage, Zero Sensor, Processor, Memory, Calibration |
| Cable Requirements | Power/Analog 3-wire shielded cable Maximum distance is 13,300 feet with 14 AWG |
| I/O Protection | Over-voltage, Miswiring, EMI/RFI Immunity |
'
'
'