021 -2216 3350
info@bapj.co.id

Teledyne Detcon IR-700-CO2 Carbon Dioxide Sensor

Update Terakhir
14 OKTOBER 2025
Negara Asal
UNITED STATES
Pembelian minimum
1
Harga
NEGO
Minta Penawaran
Sharing:

Deskripsi produk

Teledyne Detcon IR-700-CO2 Carbon Dioxide Sensor

Teledyne Detcon IR-700-CO2 Carbon Dioxide Sensor

The Teledyne IR-700-CO2 is a non-intrusive “Smart” sensor designed to detect and monitor carbon dioxide gas in air using miniature non-dispersive Infrared Optical (NDIR) sensor technology. Available in a low and a high range version, ranges of detection (by volume) are 0-0.3%, 0-1%, 0-3%, 0-5% (low range version) and 0-10%, 0-25%, 0-50%, and 0-100% (high range version). The plug-in, field-replaceable detector provides a selective response to CO2 and features oversized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual-layer surge protection.

This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model IR-700-CO2 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR700-CO2 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Additional integration options include a Remote Alarm Module (RAM) & HART. Detcon’s carbon dioxide gas sensor has an infinite shelf life and is supported by a 5-year pro-rated warranty.

Failsafe User-Friendly Interface

  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics

Environmentally Bulletproof

  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof,Vibration-Proof

Modular and Serviceable

  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port
Heading Detail
System Specifications Continuous diffusion/adsorption, Non-dispersive Infrared Optical (NDIR) - CO2, Sub-miniature plug-in field replaceable
Sensor Life 5 years typical
Measurement Range (% by volume) 0-0.3, 0-0.5, 0-1, 0-3, 0-5 (low range version), 0-10, 0-15, 0-20, 0-25, 0-50, 0-100 (high range version)
Accuracy/Repeatability ±5% of range
Response Time T50 < 15 seconds, T90 < 40 seconds
Outputs Linear 4-20 mA DC, RS-485 MODBUS-RTU
Electrical Classification Explosion proof, cCSAus, Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C), Class I, Zone 1, Group IIB+H2, ATEX, II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C)
Ingress Protection NEMA 4X, IP66
Safety Approvals cCSAus, ATEX, CE Marking
Warranty Plug-in detector - 5 year pro-rated, Transmitter - 2 Years
Environmental Specifications Operating Temperature Range: -40°F to +167°F; -40°C to +75°C, Storage Temperature Range: -40°F to +167°F; -40°C to +75°C, Operating Humidity Range: 0-100% RH non-condensing
Mechanical Specifications Dimensions: 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only), 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box), Mounting holes (J-box) 5.5”; 140mm center to center, Weight: 2 lbs; 0.907kg (sensor only), 6 lbs; 2.72kg (w/aluminum j-box), 9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications Power Input: 11-30 VDC,
Power Consumption: Normal operation = 68mA (<1.7 watt), Maximum = 85mA (2 watts),
Inrush Current: 0.67A @ 24V,
RFI/EMI Protection: Complies with EN50270,
Analog Output: Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC), 0mA All Fault Diagnostics, 2mA In-Calibration, 4-20mA 0-100% full-scale, 22mA Over-range condition,
Serial RS-485 Output: RS-485 Modbus™ RTU,
Baud Rate: 9600 BPS (9600,N,8,1 Half Duplex),
Status Indicators: 4-digit LED display with gas concentration, Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting,
Faults Monitored: Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration,
Cable Requirements: Power/Analog, 3-wire shielded cable, Maximum distance is 13,300 feet with 14 AWG, Serial Output: 2-wire twisted-pair shielded cable specifically for use with RS-485 installations, Maximum distance is 4,000 feet to last sensor,
I/O Protection: Over-voltage, Miswiring, EMI/RFI Immunity

'

'

'

Catatan:

 

Harap Tanya stok sebelum melakukan pemesanan.

Barang akan dipacking dengan aman dan rapi.

Tidak ada complain yang diterima setelah transaksi selesai.

Tanpan video unboxing, komplain tidak akan diproses.

Terima kasih!

 

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?