Fluke 417D Laser Meter
Fluke 62 MAX+ IR Thermometer
The HVAC Troubleshooting Kit
The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy-to-use 417D Laser Distance Meter has everything you need to configure HVAC layouts and troubleshoot electrical problems. For electrical devices use the IR thermometer to test overheating issues and for HVAC layout, use the 417D to configure layout distance or area and use continuous measurement for marking references.
Fluke 417D Laser Distance Meter Additional Features:
Fluke 62 MAX+ IR Thermometer Additional Features:
417D | |
---|---|
Typical range [1] | 0.2-40 m/0.6-131 ft |
Typical measuring tolerance* [1] | 2.0 mm ± 1.5 mm/± 0.06 in *** |
Maximum measuring tolerance [2] | ± 3.0 mm/0.12 in *** |
Accuracy up to 10m (+/-) | ± 2 mm |
Display | 2 line/1 mm/1/32 in |
Display illumination | Yes |
Laser point at distance | 6/30/60 mm (10/40/100 m) |
Area | Yes |
Units setting (smallest units displayed) | 0,000m, 0' 00'' 1/32, 0 in 1/32 |
Auto laser switch off | 90 sec |
Auto power switch off | 180 sec |
General | |
Laser class | II |
Laser type | 635 nm, <1 mW |
Protection class | IP54 |
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | Up to 3,000 measurements |
Size (Hx W x D) | 11.9 x 3.8 x 2.6 cm |
Drop test | 1 meter |
Weight (with batteries) | 95g (3.35 oz) |
Temperature range: Storage | -25 °C to 70 °C (-13 °F to 158 °F) |
Temperature range: Operation | -10 °C to 50 °C (14 °F to 122 °F) |
Calibration cycle | Not applicable |
Maximum relative humidity | 85 % @ 20°F to 120 °F (-7 °C to 50 °C) |
Safety | CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II) |
EMC | 61326-1:2006 |
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C (13 °F).
[2] Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to +50 °C (14 °F to +122 °F).
[3] Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft) and to 0.15 mm/m (0.005 in/ft) for distances above 30 m (98.4 ft).
[4] Applies for 100 % target reflectivity, background illumination between 10,000 lux and 30,000 lux.
[5] After user calibration. Additional angle related deviation of ± 0.01° per degree up to ± 45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ± 0.1°.
62 MAX+ | |
---|---|
Temperature range | - 30 °C to 650 °C (-22 °F to 1202 °F) |
Accuracy (Calibration geometry with ambient temperature 23 °C +/- 2 °C) | ± 1.0 °C or ± 1.0 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C ± 3.0 °C at -30 °C to -10 °C |
Optical resolution | 12:1 (calculated at 90 % energy) |
Response time (95 %) | < 300 ms (95 % of reading) |
Spectral response | 8 to 14 microns |
Emissivity | 0.10 to 1.00 |
Display resolution | 0.1 °C (0.2 °F) |
Repeatability (% of reading) | ± 0.5 % of reading or ± 0.5 °C (whichever is greater) |
Power | 1 AA alkaline battery |
Battery life | 8 hours with laser and backlight on |
Weight | 255 g (8.99 oz) |
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
Operating temperature | 0 °C to 50 °C (32 °F to 122°F) |
Storage temperature | -20 °C to 60 °C (-4 °F to 140 °F) (without battery) |
Operating humidity | Non- condensing @ ≤ 10 °C (50 °F) ≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F) ≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F) ≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F) |
Operating altitude | 2000 meters above mean sea level |
Storage altitude | 12,000 meters above mean sea level |
Drop test | 3 meters |
Implement standard | Q/ASF01 |
Standards and agency approval | |
Compliance | IEC 61010-1: Pollution Degree 2 |
Laser safety | IEC 60825-1 Class 2, 650 nm, < 1 mW |
Ingress protection rating | IP 54 per IEC 60529 |
Warranty | 3 years |