021 -2216 3350
info@bapj.co.id

Teledyne Oldham Simtronics GD1 H2S Laser Open Path Gas Detector

Update Terakhir
11 DESEMBBER 2025
Negara Asal
UNITED STATES
Pembelian minimum
1
Harga
NEGO
Minta Penawaran
Sharing:

Deskripsi produk

Teledyne Oldham Simtronics GD1 H2S Laser Open Path Gas Detector

 

Teledyne Oldham Simtronics GD1 H2S Laser Open Path Gas Detector

The Teledyne Simtronics GD1 has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from offshore production facilities to wastewater treatment plants. At the heart of the detector is a tuneable laser diode that eliminates environmental effects from sun, rain and fog. The laser scans single absorption lines where there is no interference from other gases.

  • Non-consumptive technology
  • Fail safe, with no sleeping affects
  • Suitable for SIL 2 applications
  • No cross interference
  • Low detection levels, suitable for personnel safety
  • Negligible affects from atmospheric changes (fog, etc.)
  • Fastest possible speed of response
  • No zero-point drift, no calibration
  • HART (R) standard

Unlike traditional methods for detecting H2S (MOS or EC cell) the GD1 needs no recalibration and can replace multiple standard detectors to cover the same risk. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved while providing unparalleled service life and detector stability, thus saving on maintenance and service costs. Supplied with worldwide hazardous area approvals. Suitable for use in systems with SIL 2 requirement.

 

General
Detection method IR- New IR laser scanning
Source Tunable laser diode
Laser Class 1, eye safe
Detected gas H2S
Range 0-200 ppm*m
0-500 ppm*m
0-1000 ppm*m
0-2000 ppm*m
0-5000 ppm*m
0-20000 ppm*m
Path length 5 - 75 m
Self test Continuous
Calibration Factory set, no field recalibration
Performance
Accuracy <±4% of full range
Repeatability <±4% of full range
Response time <5 sec
Optics
Alignment ±0.30 Degree
Optics Heated (transmitter and receiver
Tolerable obscuration 98% (Allowable signal loss)
Output Signal
Standard 4-20mA sink or source
HART®
Fault signals Fault 1 mA
Beam block 2 mA
Warning 3 mA (optional)
Electrical
Power supply 24V DC, range (18 - 32V DC)
Power consumption <15 W
Cable entry 4xM25 cable entries available.
Rx and Tx wired to Junction boxes: Cable gland
Nickel plated Brass (by default or in Stainless
steel on demand)
Temperature Range
Storage -55°C to +65°C (-67°F to + 149°F)
Operating -55°C to +65°C (-67°F to +149°F)
ATEX flameproof 55°C to +75°C (-67°F to +167°F)
Humidity (operation) 100% RH
Material
Tx and Rx housing Stainless Steel (ASTM 316)
Junction Box GRP
Weight
Approx 5.5 Kg (12 lbs) per Tx or Rx
Approx 2.0 Kg (4.4 Lbs) per Tx or Rx junction box
Dimensions
Tx and Rx housing Ref. Outline drawing
Warranty
5 Years full warranty on detector system
Approvals
ATEX Tx/Rx II 2 G Ex d [op is] IIC T6/T5 Gb
ATEX JB II 2 G Ex e IIC T5 Gb
IECEX DNV 10.0002X (JB: PRE 14.0040)
Ingress IP66/IP67 according to IEC 60529
SIL Suitable for use in SIL2 systems
Accessories
GD1-X00-TT06 Alignment kit
GD1-X00-TT05 Test cell

'

'

'

 

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350