021 -2216 3350
info@bapj.co.id

Drager Pac 6000 Single Gas Detector

Update Terakhir
15 DESEMBER 2025
Negara Asal
UNITED STATES
Pembelian minimum
1
Harga
NEGO
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

Drager Pac 6000 Single Gas Detector

Product Features

  • ​for personal air monitoring
  • detection of carbon monoxide, oxygen, hydrogen sulphide or sulphur dioxide
  • time-limited up to two years

 

​The Draeger Pac 6000 is a disposable personal single-gas detection device, equipped to measure CO, H2S, SO2 or O2 reliably and precisely. The robust design, quick sensor response times, and a powerful battery ensure maximum safety for up to two years, even in the toughest conditions, with virtually no maintenance required.

  • You can rely on the Dräger Pac 6000: The personal single gas detection device warns against hazardous concentrations of carbon monoxide, hydrogen sulphide, sulphur dioxide or oxygen with precision and reliability.
  • Powerful sensors with a very low t-90 response time ensure quick reactions. The Pac 6000 is versatile thanks to its wide measurement range. For example, the CO sensor measures concentrations from 1 to 1,999 ppm, and the H2S sensor from 0.4 to 100 ppm.
  • ​The D-Light indicates whether the functionality of the device has been tested and that it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Dräger Pac 6000 features a clear, well visible colour coding, thereby minimising the chance of mistakes.
  • ​The Pac 6000 can easily handle even extreme conditions: depending on the sensor, temperatures from -40 °C to 55 °C and air pressures between 700 and 1,300 mbar can be tolerated.
  • A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating.
  • ​The large display is non-verbal and clearly indicates the respective gas concentration. Other important information, such as remaining operating time and battery capacity, is also displayed. The bright backlighting ensures clear reading of all values in the dark.
  • ​If the Dräger Pac 6000 measures hazardous gas concentrations, it sets off an audible, visual, and noticeable vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic alarm reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time even if acknowledged.
  • The Pac 6000 with oxygen sensor has two additional alarm thresholds in addition to the standard alarm threshold setting.
  • ​The Dräger Pac 6000 logs concentrations and events along with date and time. The data can be downloaded to a PC via an interface and processed further there.
  • ​All of the versions of the Pac 6000 are equipped with extremely durable DrägerSensors® and a powerful battery. Neither the sensor nor the battery need to be changed for the entire two-year maintenance-free service life of the H2S, SO2 and CO versions. The service life of the Dräger Pac 6000 starts when it is first activated. The device automatically switches off after two years.
  • The Pac 6000 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled you can quickly and easily replace it yourself. The device is then ready to use again in no time.
  • ​Function tests and calibrations can be carried out especially efficient using the Dräger X-dock® calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to short test duration and extremely low test gas consumption. The Dräger Pac 6000 is simply placed in the bump test station and automatically selects the correct setting.

 

Sensor type Single-Gas Detector
Measurable gases CO, O2, H2S, SO2
Application Personal Air Monitoring
Lifetime 2 Years
Temperature range (device) -40°C - 55°C
Battery service life 2 years (24/7)
Air humidity (relative humidity) in % 10% to 90%
Air pressure (hPa) 700 - 1300
Degree of protection (IP class) IP 68
Weight  0.23 lb
Changable filter easy to change from outside / mechanical connection
D-light Yes
TLV / STEL Yes
Peak Yes
Dual sensor No
Alarm Hold Yes
ATEX
IECEx  Ex ia I Ma Ex ia IIC T4 Ga
 c CSA us  I M1 Ex ia I Ma II 1G Ex ia IIC T4 Ga (Zone 0)
 CE Yes
GOST (EAC) Yes
Performance approval No
Shipping approval (MED) No

'

'

'

Catatan:

 

Harap Tanya stok sebelum melakukan pemesanan.

Barang akan dipacking dengan aman dan rapi.

Tidak ada complain yang diterima setelah transaksi selesai.

Tanpan video unboxing, komplain tidak akan diproses.

Terima kasih!

 

 

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross