Now there's an intrinsically safe digital multimeter (DMM) you can use in a wide range of hazardous settings. Whether you work in petroleum, chemical, or pharmaceutical environments, the 28 II Ex gives high-end test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built: drop-proof, waterproof, dust-proof (IP67). The 28 II Ex meets the following certifications:
IECEx (International)
|
|
ATEX (Europe)
|
|
NEC / CEC (North America)
|
|
PCEC (China)
|
|
Simtars (Australia)
|
|
IEx (Brazil)
|
|
EAC (Russia)
|
One tool equips you with all the testing and troubleshooting power you need wherever you go––inside or outside ATEX zones 1 or 2,. No need to carry different meters for different areas, or worry about crossing through an Ex-required zone with a non-Ex rated instrument.
Important extras keep you productive all day long in less than optimal conditions.
Access to the separate battery compartment makes it easy to change batteries or fuses without jeopardizing instrument calibration.
Accuracy SpecificationsAccuracy specifications are shown as ±(% of reading + number of digits)DC voltageRange0.1 mV to 1000 VAccuracy±(0.05% + 1)AC voltageRange0.1 mV to 1000 VAccuracy±(0.7% + 4)DC currentRange0.1 μA to 10 AAccuracy±(0.2% + 4)AC currentRange0.1 μA to 10 AAccuracy±(1% + 2)ResistanceRange0.1 Ω to 50 MΩAccuracy±(0.2% + 1)ConductanceRange60.00 nSAccuracy±(1.0% + 10)Diode testRange2.0 VAccuracy±(2.0% + 1)Duty cycleRange0.0% to 99.9%AccuracyWithin ±(0.2% per kHz + 0.1%) for rise times <1 µsCapacitanceRange10 nF to 9999 μFAccuracy±(1% + 2)FrequencyRange0.5 Hz to 199.99 kHzAccuracy±(0.005% + 1)TemperatureRange-200°C to +1090°C (-328°F to +1994°F)Accuracy±(1% + 10)°C [±(1% + 10)°F]Display counts6000 counts/19,999 counts in high-resolution modePeak captureRecord transients up to 250 usMin/Max/Avg recordingDisplay signals up to approximately 100 msAccuracy specifications are shown as ±(% of reading + number of digits)Safety CertificationsATEX{Ex} II 2G Ex ia IIC T4 Gb{Ex} I M1 Ex ia I MaNEC-500Class I, Div 1, Groups A-D, 130°CIECExEx ia IIC T4 GbEx ia I MaGOST R Ex1Ex ia IIC T4 Gb XPO Ex ia I Ma XIP6XGeneral SpecificationsPowerThree AAA batteriesBattery life: 400 hoursDisplayLCD, with backlightExternal protectionRubber holsterWarrantyThree yearsSize with holster (H x W x L)6.4 x 10.0 x 19.8 cm (2.5 x 3.9 x 7.8 in)Weight with holster700 g (1.54 lb)