021 -2216 3350
info@bapj.co.id

Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Update Terakhir
Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect
Negara Asal
AMERIKA
Pembelian minimum
1
Harga
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

Key features

  • Reports distance to multiple bridge taps up to 3,200 feet (975 m)
  • Includes test leads with ABN and piercing pin clips
  • Tests opens and shorts up to 8,000 feet (2.4 km)
  • SmartTone for exact pair identification, built-in TDR and toner
  • AC/DC voltage detection, one-button testing

Product overview: Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Fluke Networks Cable fault finder with PowerBT™ Bridge Tap Detect provides open/short circuit detection—to 8,000 feet (2.4 km) and locates multiple bridge taps up to 3,200 feet (975 m) of cable, built-in toner has five tones and patented SmartTone®for exact pair identification, reports AC/DC voltage on any two conductor, telephone, security wires, or coax cables.

Specifications: Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Maximum Length 8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable types, and 500 feet (152 meters) on cables with high loss. The tester shows -Err if the cable is too long to be correctly measured.
Representative Maximum Cable Length 8,000 feet (2,438 meters): CAT-3 Twisted Pair
8,000 feet (2,438 meters): CAT-5 Twisted Pair
6,000 feet (1,830 meters): 12/2 AC Wire
3,000 feet (900 meters): RG-6/U TV Coax
1,500 feet (457 meters): RG-174/U Coax
Minimum Length No minimum length (can read a bridge tap at 0 feet/meters). Minimum non-zero reading is 2 feet or 1 meter.
Length Accuracy "±2 feet (±0.6 m) for cables less than 10 feet (3 m)
±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m)
+/-3%+/-5 feet (±2 m) for cables longer than 200 feet (60 m)"
Distance to Bridge Tap 0 feet to 3,200 feet (975 meters)
Minimum Length of Bridge Tap 10% of the distance to the bridge tap. Dependent on the cable characteristics.
Measurement Rate Maximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
VOP Adjustable from 20 to 99, saved in flash memory.
Test Technology Time Domain Reflectometry (TDR) with 100 Ω drive impedance, 6v maximum pulse height.
Cable Type Virtually all two or more conductor cables.
Power 4 AA alkaline batteries.
Reverse Battery Protection No damage to the tester will occur if the batteries are installed backwards.
Battery Life 35 hours (typical)
Low Battery Indication LED display alternates between LO and bAtt when the battery voltage falls below 4.5v.
Maximum Output Voltage 4 voltage peak
Maximum Isolation Voltage 250 volts RMS
Voltage Measurements Range: 0 volts AC to 115 volts AC; 0 volts DC to ±150 volts DC
Accuracy: AC: +/-1%+/-2 volts (45 Hz to 65 Hz); DC: +/-1%+/-2 volts DC
High Voltage Detection AC voltage detected to 115 volts; DC voltage detected to ±150 volts.
AC voltage ≥90 volts or DC voltage ≥100 volts causes high voltage warnings to show on the display
SmartTone® (5-tones) Range 7,000 feet (2,134 meters)
Toner Range 52,800 feet (16,093 meters)
Tone Injection Approximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristics change as cable condition changes to “normal-open” from any other condition.
Impedance Range 35 Ω to 330 Ω with auto-compensation within this range. Cables with impedances outside this range will not be properly tested and may produce erratic or incorrect readings.
Temperature Range Operating: 32°F to 104°F (0°C to 40°C)
Storage: 32°F to 131°F (0°C to 55°C)
Humidity Operating: 20% to 80% relative humidity
Storage: 0% to 100% relative humidity
Operating Humidity 80% maximum at 86°F (30°C )
50% maximum at 104°F (40°C )
Operating Altitude 9,843 ft max (3,000 m max)
Weight 1 lb (454 grams)
Dimensions 7.4 in x 2.7 in x 1.4 in (18.8 cm x 6.9 cm x 3.6 cm)
Safety IEC 61010-1:2010; N10140
EMC: IEC/EN61326-1:2006
Certifications and Compliance Conforms to relevant European Union directives
Conforms to relevant Australian standards
IEC/EN61010-1 CAN/CSA-C22.2 No. 1010.1-92 + CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1