Total Phosphorus High Range Reagents - HI93763B-50
The HI93763B-50 are reagents that follow an adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method for the determination of high range total phosphorus using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.
The HI93763B-50 reagent kit contains 50 ready-to-use vials of HI93758V-0HR, 1 bottle of HI93758C-0 solution, 1 bottle HI93763B-0 molybdovanadate reagent, and 50 packets of potassium persulfate reagent. These high quality reagents follow an adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method. In this method, the persulfate digestion converts organic and condensed inorganic forms of phosphates to orthophosphate. Then the reaction between orthophosphate and the reagents causes a yellow tint in the sample. The amount of phosphorus is then measured colorimetrically. The intensity of color is determined by a compatible photometer and the concentration is displayed in mg/L (ppm) of phosphorus. These reagents are designed to be used with samples that have an expected range of 0.0 to 32.6 mg/L (ppm) phosphorus.
Hanna vials contain pre-dosed reagent so the user simply needs to add a small quantity of the sample, a packet of the potassium persulfate reagent, and heat at 150° F for 30 minutes followed by the addition of the sodium hydroxide solution and the molybdovanadate reagent to determine concentration. With pre-dosed vials, test preparation time is dramatically reduced and there is no time-consuming reagent preparation procedure or glassware cleaning. The vials and caps of the reagents have been designed to avoid accidental reagent spills. Due to the pre-dosed reagents, the amount of chemicals and handling time is also minimized.
SKU | HI93763B-50 |
---|---|
Product Name | Total Phosphorus High Range Reagents - HI93763B-50 |
Quote Required | Yes |
Package | Vials, bottles, packets |
Quantity | 50 vials (49 tests) |
Method | Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P C, vanadomolybdophosphoric acid method |
BOPANA ARGA PRIMA JAYA
Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16, RT.004/RW.013, Perwira, Kec. Bekasi Utara, Kota Bks, Jawa Barat 17122
Phone :+62 -21-2216-3350 & +62-21- 292531-86
Whatsapp : +62 812-8202-721 & +62 811-1871-501
Email : info@bapj.co.id || bopana.argaprima@gmail.com