HANNA Inst.

Acid Hydrolyzable Phosphorus Reagents - HI93758B-50

The HI93758B-50 are reagents that follow an adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method for the determination of acid hydrolyzable phosphorus using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability.

  • Pre-made reagents for ease of use
  • Supplied with certificate of quality
  • Marked with expiration date and lot number for traceability

The HI93758B-0 reagent kit contains 50 ready-to-use vials of HI93758V-0AH, 1 bottle of HI93758B-0 solution, and 50 packets of HI93758-0 phosphorus reagent. These high quality reagents follow an adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method. In this method, the reaction between orthophosphate and the reagent causes a blue tint in the sample. The amount of phosphorus is then measured colorimetrically. The intensity of color is determined by a compatible photometer and the concentration is displayed in mg/L (ppm) of phosphorus. These reagents are designed to be used with samples that have an expected range of 0.00 to 1.60 mg/L (ppm) phosphorus.

Hanna vials contain pre-dosed reagent so the user simply needs to add a small quantity of the sample to the vial along with a packet of the potassium persulfate reagent followed by heating 30 minutes at 150°C and cooling, then the addition of the NaOH solution to use as the blank, followed by the addition of the powder reagent to measure the concentration. With pre-dosed vials, test preparation time is dramatically reduced and there is no time-consuming reagent preparation procedure or glassware cleaning. The vials and caps of the reagents have been designed to avoid accidental reagent spills. Due to the pre-dosed reagents, the amount of chemicals and handling time is also minimized.

Specifications :

 

SKU HI93758B-50
Product Name Acid Hydrolyzable Phosphorus Reagents - HI93758B-50
Quote Required Yes
Package Vials, bottle, and packets
Quantity 50 tests
Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method

BOPANA ARGA PRIMA JAYA

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16, RT.004/RW.013, Perwira, Kec. Bekasi Utara, Kota Bks, Jawa Barat 17122

Phone                  :+62 -21-2216-3350  & +62-21- 292531-86

Whatsapp          : +62 812-8202-721 & +62 811-1871-501

Email                   : info@bapj.co.id || bopana.argaprima@gmail.com

Website              : www.bapj.co.id

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?