Amprobe UAT-610 Underground Utilities Locator Kit
- Multiple tracing modes allow you to locate and trace energized and de-energized utilities in a variety of applications
- The intuitive Transmitter automatically chooses the correct locating function based on the connected accessory and includes selectable 8/33 kHz frequencies
- The Receiver’s high-contrast display allows for clear viewing in full sunlight and features an automatic backlight for shaded and dark areas
- Semi-automatic gain control quickly detects tracing signal and allows precise adjustment of the receiver sensitivity
- Depth measurement up to 20 ft
- Rated CAT IV 600 V, ensuring safety when working with energized cables
- Rugged, durable construction: water and dust resistant to IP54 and drop proof to 3.28 ft (1 m)
- Use the Signal Clamp to induce a signal without making electrical contact (included with the UAT-620)
- Ground fault locating with the optional A-Frame accessory
Description
Accidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations. Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company. Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground utilities and buried services up to 100 feet deep with accurate depth measurement to 20 feet.
The locating kit comes complete and ready for use with a Transmitter, Receiver, test lead kit, batteries and additional fuses, all in a mobile, protective duffle bag. The UAT-620 kit also includes a Signal Clamp for transmitting a signal when it is not possible to make electrical contact with the cable to be traced. For applications where ground fault locating is required, use the UAT-600 Transmitter in combination with the optional A-Frame accessory.
Main applications
- Locate energized 50/60 Hz cables carrying current
- Identify the location of all metallic utilities: pipes*, energized and de-energized cables
- Trace individual pipes* or cables (energized or de-energized)
*Tracing of non-metallic pipes and conduits is possible after inserting metal fish tape or cable
Three testing modes for wide range of applications
- Passive power mode (50/60 Hz) – tracing energized lines conducting current (no Transmitter necessary)
- Passive radio mode (RF) – using surrounding radio waves to trace underground utilities (no Transmitter necessary)
- Active mode using UAT-600-T Transmitter
Three active modes using the UAT-600-T Transmitter
- Induction – the Transmitter will automatically start to radiate a signal around it using an internal antenna, used for tracing individual cables where there is no access to the line to connect test leads or a clamp
- Direct connection with test leads – the most reliable method to trace individual cable or a pipe
- Clamp (Included in the UAT-620 kit, optional for the UAT-610 kit) – provides an efficient and safe method of applying a locate signal to a cable, where it is not possible/safe to gain access to a cable for making an electrical contact
Special applications
- 2 frequency options: 8 kHz and 33 kHz
- Locate non-metallic pipes and sewer lines
- Take depth and current measurements
- Measure voltage, resistance and output current
- Advanced locating with two people
- Locate ground faults with the optional AF-600 A-Frame accessory
Unparalleled safety
Stop compromising time and safety. What truly sets the UAT-600 Series apart from other underground locators is its CAT IV 600 V safety rating. This allows you to safely connect the Transmitter directly to an energized line up to 600 V in a CAT IV environment. Previously, if a crew needed to trace a specific electrical line by transmitting a signal through it, the line had to be de-energized first, adding time and reducing productivity.






Winner – 2019 Cabling Innovators Silver Award
Additional information
| Measurement Category |
CAT IV 600 V |
| Locates energized/de-energized wires, cables, pipes |
• |
| Passive tracing - 50/60 Hz |
• |
| Passive tracing - Radio |
• |
| Active Tracing |
33 kHz (de-energized) 8kHz (energized system) |
| Active tracing - Induction mode (33kHz) |
• |
| Depth measurement |
Up to 20 ft (6 m) |
| Signal Clamp accessory |
(optional accessory) |
| A-Frame accessory |
(optional accessory) |
| Null and peak tracing options |
• |
| Display |
LCD |
| Sonde capable |
• |
| Auto display backlight sensing (Receiver) |
• |
Specifications
| Measurement category |
CAT IV 600 V |
| Operating voltage/current |
0 to 600 V |
0 to 600 V, 100 A max. |
| Operating frequency/tracing modes |
Active tracing: 33 kHz and 8 kHz
Passive tracing: 50/60 Hz and Radio |
Energized circuit
Induction mode: 33 kHz
Direct connection modes: 8 kHz and 33 kHz
Clamp mode: 8 kHz and 33 kHz
De-Energized circuit
Induction mode: 33 kHz
Direct connection modes: 8 kHz, 33 kHz, A-Lo/A-Hi
A-Frame: 8 kHz
Clamp mode: 8 kHz and 33 kHz |
33 kHz and 8 kHz |
| Locating modes |
Peak and Null |
– |
– |
| Depth measurement and accuracy |
Up to 20 ft
4 in to 10 ft: pm; 3 %
10 ft to 20 ft: pm; 5 % |
– |
– |
| Display backlight |
Automatic |
Yes |
– |
| Audio indication |
Increasing closer to the signal |
Fast beeps showing the better signal is applied |
– |
| Transmitting mode power output |
– |
Max. 3 watts |
– |
| Output voltage |
– |
Max. 50 V rms |
– |
| Output current |
– |
Max. 250 mA rms, constant current in 5 steps |
– |
| Signal voltage output (nominal) |
– |
– |
23 V rms at 8 kHz
30 V rms at 33 kHz |
| Mains voltage measurement |
– |
0 V to 600 V, 50 Hz to 60 Hz
Resolution: 1 V
Accuracy: pm; 10% |
– |
Resistance measurement
(De-energized circuit) |
– |
0 ohm; to 999 k ohm;
Range: 0 ohm; to 999 ohm; (resolution: 5 ohm;)
Range: 1 k ohm; to 999 k ohm; (resolution: 1 k ohm;)
Accuracy: pm; 10% |
– |
| Output hazardous voltage warning |
– |
≥ 30 V rms |
– |
| Mains hazardous voltage warning |
– |
≥ 30 V rms |
– |
| Sensitivity adjustment (gain control) |
Yes |
– |
– |
| Sensitivity at 1 m (typical) |
Power: 2 mA
Radio: 20 μA
8 kHz: 5 μA
33 kHz: 5 μA |
– |
– |
| Display |
4.3 in, 320 x 240 BW outdoor LCD display with auto backlight |
LCD display (LED backlight)
2.4 in x 1.3 in |
– |
| Update rate |
Instantaneous |
Current (mA): 10 ms
Voltage (V): 15 ms
Resistance ( ohm;): 330 ms |
– |
| Operating temperature and humidity |
-4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH |
| Storage temperature and humidity |
-40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH |
| Operating altitude |
< 6561 ft (< 2000 m) |
| Pollution degree |
2 |
| Water and dust resistance |
IP54 |
| Drop proof |
3.28 ft (1 m) |
| Power supply |
(6) 1.5 V AA alkaline batteries |
(8) 1.5 V D cell alkaline batteries |
– |
| Auto power off |
15 minutes idle |
– |
– |
| Battery life |
Approx. 35 hours at 70 °F (21 °C) (Typical) |
Approx. 16 hours at 70 °F (21 °C) (Typical) |
– |
| Overload protection |
– |
600 V rms
Fuse FF 500 mA, 1000 V, IR 30 kA, Φ6.3×32 mm |
– |
| Agency approval |
     |
| Safety compliance |
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033 |
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
IEC 61010-031, CSA/UL 61010-031 (test leads) |
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033 |
| Size (H x W x L) |
Approx. 11.9 x 4.7 x 30.7 in (302 x 120 x 779 mm) |
Approx. 14 x 9 x 4.7 in (355 x 230 x 120 mm) |
Approx. 11.6 x 7.1 x 1.4 in (295 x 180 x 37 mm) |
| Weight |
Approx. 4.2 lb (1.9 kg) (batteries installed) |
Approx. 7.0 lb (3.2 kg) (batteries installed) |
Approx. 1.9 lb (0.85 kg) |
|
What’s Included
- UAT-600-R Receiver
- UAT-600-T Transmitter
- CC-UAT-600 Carrying Case
- TL-UAT-600 Test Leads Kit (black test lead with detachable black alligator clip, red test lead with permanently attached red alligator clip, ground stake)
- 2 x FP-UAT-600 Replacement Fuses
- 6 x AA Batteries
- 8 x D Batteries
Optional Accessories:
- SC-600 Signal Clamp
- AF-600 A-Frame Ground Fault Locator
- TL-600-25M Extension test lead, 80′ (25 m)
| UAT-600-R Receiver |
● |
● |
| UAT-600-T Transmitter |
● |
● |
| CC-UAT-600 Carrying Case |
● |
● |
| TL-UAT-600 Test Leads Kit |
● |
● |
| FP-UAT-600 Replacement Fuse |
● |
● |
| User Manual |
● |
● |
| Quick Reference Guide |
● |
● |
| 6 x 1.5 V AA (IEC LR6) Batteries (Receiver, not installed) |
● |
● |
| 8 x D-Cell Batteries (Transmitter, not installed) |
● |
● |
| SC-600 Signal Clamp |
– |
● |
BOPANA ARGA PRIMA JAYA
Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16, RT.004/RW.013, Perwira, Kec. Bekasi Utara, Kota Bks, Jawa Barat 17122
Phone :+62 -21-2216-3350 & +62-21- 292531-86
Whatsapp : +62 812-8202-721 & +62 811-1871-501
Email : info@bapj.co.id || bopana.argaprima@gmail.com
Website : www.bapj.co.id