021 -2216 3350
info@bapj.co.id

1-6112-01-28 Compact Cool Incubator with Pre-shipment Validation ICI-1

Update Terakhir
Negara Asal
Jepang
Pembelian minimum
1
Harga
Nego
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

Order No. 1-6112-01-28
Model No. ICI-1
JAN Code 4589638434631

Features

  • Cool incubator using Peltier element.
  • This is a forced convection system that circulates the internal air with a small fan.
  • PID control with high temperature control accuracy is adopted.

Spec

  • Validated products are Azuwan original services that conduct FAT (Factory Acceptance Test) at Azuwan before shipping.
  • Validate (FAT) before shipping.
  • After receiving the order, a FAT instruction form (plan) is sent to the user, and after the signature is returned, the FAT is performed.
  • Appendix: FAT report/Calibration Certificate of used measuring instrument copied
  • *I am attaching Azwan's original FAT instruction manual (see the sample at the bottom left of the Screen).
  • Temperature points: 3 points at 37 degrees Celsius
  • Body dimensions: 270 x 210 x 260 mm
  • Internal dimensions: 220 x 160 x 130 mm
  • Mesh size: 200 x 145 mm
  • Temperature setting range: + 12 ~ 50 deg.
  • Operating ambient temperature: 12 ~ 26 degrees Celsius
  • Temperature distribution: +/- 1.5 degrees C
  • Forced convection system
  • Temperature control method: PID control
  • Temperature Sensor: K thermocouple
  • Material: Body/ABS, Clear Cover/PS (Polystyrene), Net Plate/Stainless Steel (SUS 304)
  • Body weight: 3.2 kg
  • Power supply: 100 VAC 50/60 Hz
  • Power consumption: 40 W
  • Power cord length: 2 m (2P plug)
  • Accessory: 1 rack
  • Local validation services (IQ/OQ) are also available. Please contact us.
  • *The on-site validation service is a service that performs installation qualification (IQ) and operational performance qualification (OQ) at the installation site and submits an inspection form.
  • *Since this product is a physical and chemical culture and refrigeration equipment, it may not be used for medical treatment or similar activities or purposes.
  • *If you would like to request a local IQOQ, please contact us separately. We need your installation address for the estimate.




Hubungi:
PT Bopana Arga Prima Jaya
Jalan Jupiter VI Perum Bintang Metropol
Blok A7 No.16 Bekasi Utara 17122
Jawa Barat, Indonesia
Telp : 021-22163350
Hp : 08119762505 / 081285345374
Email : boney@bapj.co.id / tesa@bapj.co.id

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross