Sensor information PCE-AC420-210
- Range Measuring 0.2 ... 20 mm / s
- Linear frequency range (± 3 dB) 10 ... 1000 Hz
- Degree of protection IP67
- Shielded connector 713 (M12), axial
- Approx. 66 g
| Technical Specifications - PCE-AC420-210 Sensor | |
| Measuring range (RMS) at 4-25-mA | 0.2 ... 25 mm / s |
| Nominal value (RMS) at 20-mA | 20 mm / s |
| Sensitivity | 0.8-mA / mms-1 |
| 3 dB lower frequency limit | 10 Hz |
| 3 dB upper frequency limit | 1000 Hz |
| Stabilization time at 1% tolerance | 2 s |
| Loop supply voltage | 12 ... 30V |
| Destruction limit | ± 4000 g / 8.8 lbs |
| Transverse sensitivity | <5% |
| Operating temperature | -40 ... 85ºC / -40 ... 185ºF |
| Type of protection | IP67 |
| Weight without cable | 66 g / 2.3 oz |
| Shell material | Stainless steel |
| Connector | Male connector |
| Mounting | M8 threaded hole |
| Technical specifications - PCE-DPD-U screen | |
| Screen | 4-digit red LED |
| Digit Height | 14 mm |
| Processes | Vexc +15 Vdc configurable in terminal 5 |
| Response time | < 300 mSec (0% to 99% signal) |
| 'U' power | 18 to 265V AC / DC (isolated 1500 Veff @ 60 sec.) |
| Power | 230V AC / 24V (depending on version) |
| Entry | 4 ... 20-mA |
| Departures | SLOT1: relay R1 included (optionally, you can request analog output 4-20..A or RS485 Modbus RTU output) SLOT2: empty (optionally, you can request a relay relay R2, if R1 is already installed) |
| Type of protection | IP65 |
| Connections | Screw plug-in terminal |
| Feeding | 18… 265V AC (50 / 60Hz) / DC |
| Environmental conditions | 0 ... 50°C / 32 ... 122°F |
| Weight | < 150 grams |
| Dimensions | 96 x 48 x 91 mm / 3.8 x 1.9 x 3.6 in (including terminal) |
| General specifications | |
| Regulations | To control machinery for predictive maintenance according to ISO2372, ISO10816, ISO20816, etc. |
| Alarm | Configurable setpoint |