Easily and accurately locate wires, breakers, and fuses with the AT-6010 Advanced Wire Tracer. When the Transmitter is connected to the circuit (Energized or De-energized, up to 600 V AC/DC in Category I through Category III electrical environments), the Receiver easily detects the transmitted signal in the wires or cables behind walls, ceilings and floors. Work safely on energized circuits without the need to take equipment offline. The Transmitter also features high signal mode for general tracing and a loop mode designed specifically for locating shorts, as well as two optimal tracing frequencies that are automatically activated based on the detected voltage. The AT-6010 can be combined with the CT-400 Signal Clamp (optional accessory) for applications where access to circuit contacts is limited or where users are not able to connect the Transmitter to the circuit through test leads.
![]()
![]()
![]()
![]()
![]()
Winner – Tool Innovation Awards Electrical Specialty
| Measurement Category | CAT III 600 V |
|---|---|
| Traces energized and de-energized wires | • |
| Locates energized and de-energized breakers and fuses | • |
| Receiver "Breaker Identification" mode | – |
| Finds shorts and opens | • |
| Transmitter "Loop" mode | – |
| Non-contact voltage detection | – |
| Two frequency modes | • |
| Transmitter Operating Voltage | 0 to 600 V AC/DC |
| Receiver Display | B&W 2.5 in LCD |
| Rechargable Batteries | – |
| Signal clamp attachment | Optional |
| Features | AT-6010-R Receiver | AT-6010-T Transmitter |
| Measurement category | CAT III 600 V | |
| Operating voltage/current | 0 to 600 V | |
| Operating frequency | Energized: 6.25 kHz | |
| Hazardous voltage detection | N/A | > 30 V AC/DC |
| Signal indications | Numeric bar graph display and audible beep | LEDs |
| Response time | Tip Sensor (Energized/De-energized): 500 ms Battery voltage monitoring: 5 sec |
Line voltage monitoring: 1 sec Battery voltage monitoring: 5 sec |
| Current output of signal (typical) | N/A | Energized circuit: HI mode: 60 mA RMS De-energized circuit: HI mode: 130 mA RMS Loop mode: 160 mA RMS |
| Signal voltage output (nominal) | N/A | De-energized circuit: HIGH: 33 V RMS, 140 Vp-p With CT-400: Loop model: 31 V RMS, 120 Vp-p |
| Range detection (open air) | Tip Sensor (Energized): Max distance via air: up to 20 ft (6.1 m) Pinpointing: approx. 1.97 in (5 cm) Tip Sensor (De-energized): Max distance via air: up to 14.7 ft (4.5 m) Pinpointing: approx. 1.97 in (5 cm) |
N/A |
| Display size | LCD 2.5 in (6.35 cm) | N/A |
| Display dimensions (W x H) | 1.45 x 1.93 in (36.72 x 48.96 mm) |
N/A |
| Display type | Segment LCD | LEDs |
| Display color | Black and white | Operating mode LEDs: red Battery status LED: red |
| Booting time | < 3 sec | < 2 sec |
| Backlight | Yes | N/A |
| Operating temperature | -4 °F to 122 °F (-20 °C to 50 °C) | |
| Operating humidity | 45%: -4 °F to <50 °F (-20 °C to <10 °C) 95%: 50 °F to <86 °F (10 °C to <30 °C) 75%: 86 °F to <104 °F (30 °C to <40 °C) 45%: 104 °F to 122 °F (40 °C to 50 °C) |
|
| Storage temperature and humidity | -4 °F to 158 °F (-20 °C to 70 °C), <95% RH | |
| Operating altitude | 0 to 6561 ft (2000 m) | |
| Transient protection | N/A | 6.00 kV (1.2/50μS surge) |
| Pollution degree | 2 | |
| IP rating | IP 52 | IP 40 |
| Drop test | 3.28 ft (1 m) | |
| Power supply | 4 x AA (alkaline) | 8 x AA (alkaline) |
| Power consumption (typical) | 70 mA | Hi mode: 70 mA Loop mode with Clamp: 90 mA Consumption without signal transmission: 10 mA |
| Battery life | Approx. 25 h | Hi mode: approx. 25 h Loop mode: approx. 18 h |
| Low battery indication | Yes | |
| Fuse | N/A | 1.6 A, 700 V, fast-acting, Ø 6x32mm |
| Dimensions (L x W x H) | Approx. 7.2 x 2.95 x 1.69 in (183 x 75 x 43 mm) |
Approx. 7.2 x 3.66 x 1.97 in (183 x 93 x 50 mm) |
| Weight | Approx. 0.6 lb (0.27 kg) | Approx. 1.25 lb (0.57 kg) |
| Certifications | ||
Refer to user manual for accessory specifications
| AT-6010-R Receiver | • |
| AT-6010-T Transmitter | • |
| TL-6000-INTL Test lead and accessory kit* | • |
| CC-6010 Soft carrying case | • |
| User Manual | • |
| Quick Reference Guide | • |
| 1.5 V AA (IEC LR6) Battery | 12 |