021 -2216 3350
info@bapj.co.id

CLAMP LOGGER LR5051

Update Terakhir
CLAMP LOGGER LR5051
Negara Asal
JEPANG
Pembelian minimum
1
Harga
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

Easily Record Load Current of 50Hz/60Hz Lines and Leak Current

Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5051 logs current over 2 channels in as fast as 1 second intervals.

*Clamp sensor is sold separately

Key Features

  • Easily mount the light-weight, pocket-sized loggers in tight spaces
  • Easy-to-see dual display
  • Transfer data to PC even during recording*
  • Replace batteries while recording (30 second limit)
  • 3 times the memory capacity compared to predecessor (Record 60,000 data per channel)
  • Record without missing fluctuations in STAT mode
  • Measurement data is preserved even after the battery dies
  • Worry-free backup preserves recorded data even if a new measurement is started by mistake
  • *Optional accessory is required and sold separately.
Note: The Clamp Logger LR5051 may be affected by high-frequency noise while measuring leak current. Please contact Hioki for more information if you plan to use the instrument in an environment where it would be subject to the effects of high-frequency noise.
Customers using the previous Model 3636-20 Clamp Logger should note that the LR5051 can only record 15,000 points of average data, vs. 32,000 data points available in the 3636-20.
Communication Adapter LR5091 or Data Collector LR5092-20 is necessary to collect data from the LR5000 series Logger and transfer data to a PC.

Basic specifications

Accuracy guaranteed: 1 year
Measurement items AC Current 2 channels (used with the optional current sensor; load current 2ch, leak current 2ch, or load/leak each 1ch)
Caution: Current and leak current that occur intermittently cannot be measured.
Measurement range 500.0 mA to 1000 A AC rms, 5 range (depends on current sensor in use)
Basic accuracy ±2.0% rdg. ±0.13% f.s. (main unit + current sensor accuracy, at 500.0 A range, 50/60 Hz)
Note: Basic accuracy is typical value, only main unit accuracy: ±0.5 %rdg. ±5 dgt., must added clamp sensor accuracy, refer to the detailed catalog
Storage capacity Instantaneous value mode: 60,000 data/ch, Statistical value mode: 15,000 data/ch
Recording interval 1 to 30 sec., 1 to 60 min., 15 selections
Recording modes Instantaneous recording: at every recording interval
Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval
Recording methods One-time recording: Stop recording when the memory capacity is full
Endless recording: Continue recording even when the memory capacity is full (old data is overwritten)
Start: Logger button operation or scheduled time
Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording)
Other functions Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced
Waterproof and dust-proof N/A
Interfaces Infrared optical communications with LR5091, LR5092-20
Power supply LR6 (AA) Alkaline battery ×2, Battery life: Approx. 1 year (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 1 month (Instantaneous recording, with 1-second interval at 20 °C)
Dimensions and mass 79 mm (3.11 in) W × 70 mm (2.76 in) H × 37 mm (1.46 in) D, 165 g (5.8 oz)
Included accessories LR6 (AA) Alkaline battery (built-in internal) × 2, Instruction manual × 1, Operation guide × 1

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?