Crowcon Vortex FP Fixed Gas Detection Control Panel Crowcon
Simple to Use:
|
VORTEX
|
VORTEX RACK/PANEL
|
|
|
SIZE
|
440 x 640 x 332mm (17.3 x 25 x 13 ins)
|
450 x 330 x 289mm (17.6 x 13 x 11.4 ins)
|
|
WEIGHT
|
70Kgs (154lbs) approx.
|
37.5kgs (83lbs) approx.
|
|
ENCLOSURE MATERIAL
|
LM25 aluminium with polyester powder coating
|
|
|
INGRESS PROTECTION
|
IP66
|
|
|
CHANNELS
|
Up to 12 (1 to 3 4-way input modules)
|
|
|
OPERATING TEMPERATURE
|
-10°C to +40°C (14°F to +140°F)
|
|
|
HUMIDITY
|
0-95% RH non-condensing
|
|
|
INPUTS
|
Gas 2 or 3 wire 4-20mA (sink or source), 0-5V
|
|
|
-Fire – smoke & heat detectors, manual call-points Up to 3 loops, Up to 20 devices per loop
|
||
|
OUTPUTS
|
External audible/visual alarm drive Via relays, four 24Vdc 0.5A supplies provided.
|
|
|
RELAYS
|
Type Up to 32 SPCO with bus extension module
|
Relay limitations: 1 or 2 input modules: 2 relay modules max. (16 relays) 3 input modules: 1 relay module only (8 relays)
|
|
Assignment – Common Battery back-up not available
|
||
|
Assignment – Voting Alarms, faults and system events
|
||
|
Relay modes Energised/de-energised, latched/non-latched, time-delayed, pulsed
|
||
|
DIGITAL COMMUNICATIONS
|
DCS/PLC/PC: RS-485 Modbus or Profibus
Local configuration link: RS-232 (configuration software and lead supplied)
|
|
|
EVENT LOGGING
|
Up to 300 alarm, power, fault, and system events are stored in Non-Volatile Memory
|
|
|
PANEL INDICATION
|
Channel number: 2-digit 7-segment Green LED
Gas reading: 4-digit 7-segment Red LED
Measurement units: % LEL, ppm, % Vol, Fire
Power: Green LED
Battery OK: Green LED
Run/hold indication: Green LED
Channel test mode: Flashing Amber LED
System fault – integrity watchdog: Amber LED
Displayed information can be altered and outputs can be inhibited during calibration using a magnetic key
|
|
|
ALARM INDICATION
|
Audible – internal sounder: Piezo
Visual – Alarm: Level 1 & 2, Red LED; Fault – Per channel, Amber LED; Inhibit – Per zone, Amber LED
|
|
|
POWER
|
AC mains/DC: 110 or 240Vac 3.2A max 150W PSU 20 – 30Vdc
|
|
|
Battery backup: not available
|
||
|
APPROVALS
|
Low voltage directive: EN61010-1
EMC: Directive 2014/30/EU: EN50270, FCC: CRF47 Part 15, ICES-003
ATEX: Ex II 2G D Zone 1, Zone 2, IECEx optional
|
|
|
FUNCTIONAL SAFETY
|
Validated to IEC61508
|
|
'
'
'
Catatan: