021 -2216 3350
info@bapj.co.id

Crowcon Xgard Bright Crowcon

Update Terakhir
10 OKTOBER 2025
Negara Asal
UNITED STATES
Pembelian minimum
1
Harga
NEGO
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

Crowcon Xgard Bright Crowcon

The Crowcon Xgard Bright Fixed Multi-Gas Detector is a versatile detector offering flammable and toxic gas detection and oxygen monitoring, while providing ease of operation and reduced installation costs.

Choose from durable sensor options to suit your needs, such as MPS (10+ years), Long-life O2 (5 years) and IR sensors (10+ years) to prevent frequent sensor replacements and minimise operational expenses.

Lowering the cost of installation, the 4-wire addressable implementation drastically reduces cabling requirements. The large OLED display allows users to easily work with Xgard Bright during installation, calibration and routine maintenance without the need to open the housing.

Providing analogue 4-20mA and RS-485 Modbus signals as standard, Xgard Bright comes with an Alarm and Fault relay as standard as well as optional HART communications.

Size 156 x 166 x 109mm (6.1 x 6.5 x 4.3inch)
Cable Entry 2x M20 (stopping plug fitted to left-side entry)
Power 10-30Vdc. 3W max
Electrical Output 4-20mA current sink or source
RS-485 Modbus RTU
HART (Optional)
Weight Aluminium alloy 1kg (2.2lbs)
Enclosure Material ADC 12 aluminium alloy
Relay Alarm 1, Alarm 2, Fault 

SPST contacts rated 1A 30Vdc

Sounder Out 24Vdc (nominally), 250mA maximum load
Operating Temperature -40°C to +70°C (-40°F to 158°F) 

Note: sensor operating temperatures vary widely.

Refer to the sensor module datasheet or contact

Crowcon for specific sensor data.

Humidity 0 to 95% RH, non-condensing
Repeatability +/- 2% FSD
Zero drift +/- 2% FSD per year maximum
Ingress protection IP65 (IP66 with weatherproof cap)
Approvals ATEX and IECExEx II 2 G Ex db IIC T6 Gb 

Ex tb IIIC T80ᶜ Db

II 2 G Ex db IIC T6 Gb

II 2 D Ex tb IIIC T80ᶜ Db

Certificate numbers:

TUV 16 ATEX 7908 X

IECEx TUR16.0035 X

EMC Compliance EN50270: 2015
Standards EN60079-0 :2012 + A11:2013
EN60079-1 :2014
IEC60079-0 :2011 Edition 6
IEC60079-1 :2014 Edition 7
Zones Certified for use in Zone 1 and Zone 2 areas

Gases and Ranges

Gas Units Max
Range
Standard
Range
Alarm 1
level
Alarm 2
level
Temp
range °C 
MPS Flam %LEL 100 100 20 40 -40 to +75
Oxygen (O2) %Vol 30 25 19 (falling) 17 (falling) -20 to +50
Carbon Monoxide (CO) PPM 1000 250 30 200 -30 to +50
Hydrogen Sulphide (H2S) PPM 100/200 25 5 10  -30 to +50
Hydrogen (H2) %LEL 100 100 20 40 -40 to +75
Methane (CH4) %LEL 100 100 20 40 -40 to +75
Pentane (C5H12) %LEL 100 100 20 40 -40 to +75
LPG %LEL 100 100 20 40 -40 to +75
Carbon Dioxide (CO2) %VOL 0-5% 0-5% 0-2% 0-3% -20 to +50
PID (VOC) – Safe Area PPM 1000 1000 30 50 -20 to +50
Infra Red Methane (CH4) %LEL 100 100 20 40 -40 to +75
Infra Red Propane (C3H8) %LEL 100 100 20 40 -40 to +75
Ammonia (NH3) – Safe Area PPM 100 50 25 25 -20 to +40
Chlorine (CL2) – Safe Area PPM 10 5 1 3 -20 to +40
Ozone (O3) – Safe Area PPM 1 1 0.1 0.2 -20 to +40
Sulphur Dioxide (SO2) – Safe Area PPM 100 10 1 1 -30 to +50
Infra Red Butane (C4H10) %LEL 100 100 20 40 -40 to +75
Infra Red Pentane (C5H12) %LEL 100 100 20 40 -40 to +75
Infra Red LPG %LEL 100 100 20 40 -20 to +55

'

'

'

Catatan:

 

Harap Tanya stok sebelum melakukan pemesanan.

Barang akan dipacking dengan aman dan rapi.

Tidak ada complain yang diterima setelah transaksi selesai.

Tanpan video unboxing, komplain tidak akan diproses.

Terima kasih!

 

 

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?