021 -2216 3350
info@bapj.co.id

CURRENT UNIT 8971

Update Terakhir
CURRENT UNIT 8971
Negara Asal
JEPANG
Pembelian minimum
1
Harga
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

Dedicated Current Input Module Capable of Supplying Power to Current Sensors

Key Features

  • Clamp connection, up to 500 A AC/DC, automatic sensor identification, easy operation
  • 2 channel input
  • From low to high frequency, wide bandwidth RMS rectifier installed (DC, or 30 Hz to 10 kHz)
  • Monitor instantaneous waveforms without the need to pass through the rectifying circuit
  • High 12-bit A/D resolution
    *Not available for MR8741
Note: This module must be used with the Memory HiCorder. Current sensors are not supplied. Please purchase the appropriate sensors for the intended application.

Basic specifications

Accuracy guaranteed: 1 year
Measurement functions Number of channels: 2 CH, Current measurement with optional current sensor.
Up to four modules of 8971 can be used with a Memory HiCorder (models compatible with installation).
Input connectors Sensor connector (input impedance 1 MΩ, exclusive connector for current sensor via conversion cable the 9318, common ground with recorder)
Applicable current sensor 9272-05, CT6841A, CT6843A, CT6844A, CT6845A, CT6846A, CT6862-05, CT6863-05, CT6872、CT6872-01, CT6873, CT6873-01, CT6875A, CT6875A-1, CT6876A, CT6876A-1, CT6904A, CT6904A-1, CT6904A-2, CT6904A-3

*Connect the optional Conversion Cable CT9901 {converts ME15W (12pin) terminal to PL23 (10pin) terminal} in combination with the 9318 supplied with model 8971.

Measurement range When Model 9272-05 (20 A), CT6841A is used: 2, 4, 10, 20, 40, 100 A f.s. (f.s. =20div, Choice of 6 ranges)
When Model CT6862-05, CT6872, CT6872-01 is used: 4, 10, 20, 40, 100, 200 A f.s. (f.s. =20div, Choice of 6 ranges)
When Model 9272-05 (200 A), CT6843A, CT6863-05, CT6873, CT6873-01, CT6904A, CT6904A-1, CT6904A-2, CT6904A-3 is used: 20, 40, 100, 200, 400, 1000 A f.s.(f.s. =20div, Choice of 6 ranges)
When Model CT6844A, CT6845A, CT6875A, CT6875A-1, CT6846A, CT6876A(*1), CT6876A-1(*1) is used: 40, 100, 200, 400, 1000, 2000 A f.s.(f.s. =20div, Choice of 6 ranges)
The measurable range is limited by the current sensor connected. Check the specifications of the respective current sensor.
*1: The instrument recognizes this as a 500 A AC/DC sensor is connected; setting the ratio of the scaling function to 2 is required.
Accuracy (with filter 5 Hz ON) Add the accuracy and characteristics of the current sensor used. Measurement accuracy: ±0.65% f.s.
RMS accuracy: ±1% f.s. (DC, 30 Hz to 1 kHz), ±3% f.s. (1 kHz to 10 kHz)
RMS response time: 100ms (rise time from 0 to 90% of full scale), Crest factor: 2
Frequency characteristics: DC to 100 kHz, ±3dB (with AC coupling: 7 Hz to 100 kHz)
Measurement resolution Uses 12-bit A/D
When used with MR8847A: 1/100th of the measuring range
When used with MR6000: 1/2000 of the measuring range
Highest sampling rate 1 MS/s (simultaneous sampling across 2 channels)
Other functions Input coupling: AC/DC/GND, Low-pass filter: 5, 50, 500, 5k, 50kHz, or OFF
Dimensions and mass 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D, 250 g (8.8 oz)
Included accessories CONVERSION CABLE 9318 × 2 (To connect the current sensor to the 8971)