Up to three virtual noise dose meters can be set in a decibel meter (badge type). This has the advantage that up to three measurement standards can measure simultaneously. The display of the noise dose meter shows up to 14 measurement windows that can be set individually.
The data transfer from the decibel meter (badge type) to a PC takes place directly via the charging station. The recorded measurement data can be read out and analyzed with the software for the noise dose meter. In addition, all settings for the noise dose meter can be made via the software. Another special feature of the noise dose meter is that the charging stations can be coupled with each other. This has the advantage that several noise dose meters can be charged via one power pack. Up to four noise dose meters can be charged simultaneously per power supply.
For optimal support and positioning, the decibel meter (badge type) is attached to the work clothing of the respective employee with two crocodile clips. The distance between hearing and the noise dose meter should be between 10 and 15 cm (3.9 and 5.9").
| Measuring range | 70 … 140 dB (A, C) |
| 90 … 140 dB (Z) | |
| Measuring range (peak value) | 103 … 143 dB PEAK |
| Resolution | 0.1 dB |
| Accuracy | class 2 |
| Frequency range | 31.5 Hz … 8 kHz |
| Frequency weightings | A, C and Z |
| Time weighting | fast, slow, impulse |
| Adjustable level increase | 3, 4, 5, 6 dB |
| Threshold adjustment range | 70 … 90 dB |
| Threshold resolution | 1 dB |
| Adjustment range of the criterion level | 70 … 90 dB |
| Resolution of the criterion level | 1 dB |
| Display if the ambient condition is too loud | >115 dB |
| Memory | 30 measurement runs with total |
| 6101 measuring points | |
| Timer | 16 timers for an automatic |
| data logging and 99 timers | |
| Warm-up time | 10 seconds after power on |
| Microphone | 1/2 inch electret condenser |
| Display | 128 x 64 pixel LC display |
| For applications according to the standard | IEC 61252:2002, ANSI S1.25-1991 |
| Number of virtual dosimeters | 3 |
| Dosimeter standards | OSHA-80, OSHA-90, MSHA-80, MSHA-90, DOD, |
| ACGIH, ISO-85, ISO-90, NR-15, NHO-01 | |
| In addition, up to 9 individual | |
| standards can be stored | |
| Measurement parameters for all | DOSE (Dose), PDOSE (Pdos), TWA (Twa), |
| virtual dosimeter | PTWA (PTwa), LAVG (Lavg), LEPd (Lepd), |
| PLEPd (PLepd), Exceed time | |
| (Las>105 or Las >115), LEQ | |
| (Laeq, Lceq, Lzeq), SEL (LaE, LCE or LZE), | |
| SEpa2h (Ea, Ec, Ez), PEAK (Pka, Pkc or Pkz), | |
| LEX8H (Lex8h), PLEX8H (PLex8h), | |
| EXPHrs (Exph), EXPsec (Exps), NEN | |
| Additional measurement parameters | MAX/MIN, L05, L10, L50, |
| for the first virtual dosimeter | L90 and L95 at a 20 ms interval |
| and a difference of 0.1 dB, | |
| LAEQ05, LAEQ10, LAEQ50, LAEQ90, | |
| LAEQ95 at a 1 s interval | |
| and a difference of 0.1 dB | |
| Interface | USB interface on the charging station |
| Power supply (battery) | 3.7 V, 470 mAh, lithium polymer battery |
| Power supply (mains adapter) | primary: 100 ... 240 V AC, 50 ... 60 Hz, 0.7 A |
| secondary: 9 V DC, 2 A | |
| Operating time | >15 hours at 23 °C / 73 °F |
| Operating conditions | 0 … 50 °C (32 … 122 °F), 10 … 95 % RH, |
| non-condensing | |
| Storage conditions | -10 … +60 °C (14 … 140 °F), 10 … 75 % RH, |
| non-condensing | |
| Dimensions | 84 x 49 x 55 mm / 3.3 x 1.9 x 2.2 inch |
| Weight | 77 g / 2.7 oz |