Economic entry-level model for the laboratory

The flame photometer FP8400 is the standard version for a variety of laboratory applications and offers a very simple operation in combination with very high precision and application flexibility in

determining the concentration of alkali and alkaline earth elements in aqueous solutions. With the models of the FP8000 series, A.KRÜSS Optronic presents to this day unique measuring devices for

the simultaneous measurement of the elements Na, K, Ca and Li. Five measuring channels are available for this, which can be individually configured. Thanks to proven measuring methods and modern

device electronics, our flame photometers achieve high-precision and reproducible measurement results and are a simple and particularly cost-effective alternative to analysis techniques such as ICP or AAS.

  • Reliable, simultaneous measurement of up to five alkaline and alkaline earth elements
  • For operation with low sample volume
  • Very high precision
  • Maximum operational safety through intelligent security mechanisms
  • User administration with two authorization levels
  • Full traceability of the measurement results
  • Extensive interfaces and convenient data transfer
  • Compliance with international standards such as GMP / GLP and 21 CFR Part 11

Model specifications

FP8400 Na K Li Ca
MEASURING RANGE 0.01-4500 ppm
0.0004-200 mmol/l
0.01-4500 ppm
0.0003-110 mmol/l
0.01-4500 ppm
0.0014-600mmol/l
0.50-4500 ppm
0.0125-110 mmol/l
DETECTION LIMIT 0.01 ppm
0.0004 mmol/l
0.01 ppm
0.0003 mmol/l
0.01 ppm
0.0014 mmol/l
0.03 ppm
0.0075 mmol/l
PRECISION 0.2 % at 40 ppm
0.2 % at 1,74 mmol/l
0.2 % at 40 ppm
0.2 % at 1,03 mmol/l
0.2 % at 40 ppm
0.2 % at 5.71 mmol/l
0.2 % at 40 ppm
0.2 % at 1.00 mmol/l
ACCURACY 1 % at 40 ppm
1 % at 1.74 mmol/l
1 % bei 40 ppm
1 % at 1.03 mmol/l
1 % at 40 ppm
1 % at 5.71 mmol/l
1 % at 40 ppm
1 % at 1.00 mmol/l
CALIBRATION Linear with 2 standards
Non linear with 6-8 standards,
cubic approximation
DRIFT 1% in 60 min
REFERENCE Lithium guideline with 35 mg/l or 5 mmol/l
Caesium guideline on request
SAMPLE VOLUME 2.5 ml
COMBUSTION GAS Propane, Butane or LPG: Recommended for alkaline elements
Acetylene for flame photometry: Recommended for alkaline earth elements
DISPLAY TFT-Display with integrated 8,4“ TFT touchscreen, 800x600 Pixel
INTERFACES 2 x USB
1 x Ethernet
1 x RS-232 for printer
EQUIPMENT Basic model
ACCESSORIES 24 character plain paper printer
Various standards and system solutions
Spare parts and accessories directly from the manufacturer
UPGRADEABILITY Retrofit kits to other models available

 




Hubungi:
PT Bopana Arga Prima Jaya
Jalan Jupiter VI Perum Bintang Metropol
Blok A7 No.16 Bekasi Utara 17122
Jawa Barat, Indonesia
Telp : 021-22163350
Hp : 08119762505 / 081285345374
Email : boney@bapj.co.id / tesa@bapj.co.id