IGM™ Infrared Guided Measurement
Upgrade your testing tool with IGM. Utilizing the FLIR Lepton® sensor, IGM visually guides you to hidden temperature issues so you know precisely where to focus your troubleshooting. Eliminate guesswork and boost efficiency. Impress customers by uncovering problems and showcasing solutions.
UNRIVALED IMAGE QUALITY
MSX® Image Enhancement
The FLIR DM286 features FLIR's unique Multi Spectral Dynamic Imaging (MSX), which adds key details from the onboard visible light camera to the entire infrared image in real time. The result: an all-in-one, undiluted thermal picture with visible light features that lets you instantly recognize where the problematic heat pattern is. MSX is real time so you can see its results immediately on the camera's display.
Pictured left to right: without MSX® and with MSX®
GET INSPECTION INFORMATION TO THE PEOPLE YOU NEED
FLIR METERLiNK® App
The FLIR METERLiNK® app allows you to monitor a variety of environmental and electrical conditions simultaneously with the ability to connect with up to seven FLIR compatible meters at once. METERLiNK allows you to safely capture images and monitor hazardous areas remotely and in real time. Whether you're connecting several FLIR clamp meters, digital multimeters, or any of the new METERLiNK app compatible meters, you will be able to keep tabs on key readings around your facility and easily share them with your team.
SPECIFICATIONS
- IR Resolution
- 160 × 120 (19,200 pixels)
- Display Counts
- 6000
- AC/DC Voltage
- 1000 V AC RMS ±(1.0%+3) 1000 V DC ±(0.09%+3)
- AC/DC Amps
- 10.00 A AC RMS ±(1.5%+3) 10.00 A DC ±(1.0%+3)
- Connectivity
- Bluetooth BLE
IMAGING & OPTICAL
- Color Palettes
- Iron, rainbow, arctic, white hot, and black hot
- Field of view - visual
- 71° × 56°
- Focus
- Fixed
- Frame Rate
- 9 Hz
- Image Modes
- Thermal MSX (Multi Spectral Dynamic Imaging)
Thermal Camera only
Digital Camera only
- IR Resolution
- 160 × 120 (19,200 pixels)
- IR Sensitivity
- 150 mK (0.15°C)
- Spectral Response
- 8–14 µm
- Thermal Imaging Detector
- FLIR Lepton® microbolometer
- Visual Focus and FOV
- Fixed focus, 71° × 56° FOV
- Visual Resolution
- 2 MP (1600 × 1200 pixels)
MEASUREMENT & ANALYSIS
- AC/DC Amps
- 10.00 A AC RMS ±(1.5%+3) 10.00 A DC ±(1.0%+3)
- AC/DC LoZ V
- 1000 V AC RMS or 1000 V DC ±(1.3%+4)
- AC/DC mVolt
- AC 600.0 mV ±(1.0%+3) DC 600.0 mV±(0.2%+3)
- AC/DC Voltage
- 1000 V AC RMS ±(1.0%+3) 1000 V DC ±(0.09%+3)
- Calibration Cycle
- Once per year, recommended
- Capacitance
- 10.00 mF ±(4.0%+5)
- Contact Temperature Type K thermocouple
- -40°C to 400°C DMM ± (1.0% + 3°C) / IGM ± (1.0% + 5°C)
(-40°F to 752°F DMM ± (1.0% + 5.4°F) / IGM ± (1.0% + 9°F)
- Continuity check threshold
- 10–100Ω
- Diode Test
- 1.500 V ± 0.9%
- Display Counts
- 6000
- Frequency Counter
- 100.00 kHz ±(0.1%+5)
- Measuring Rate
- 3 samples per second
- Resistance
- 6.000 MΩ ±(0.9%+5), 60.00 MΩ ±(3.0%+5)
- Temperature Accuracy
- ±3°C (5.4°F) or ± 3% of the reading (whichever is greater) for temperatures > 25°C (77°F) ±5°C for temperatures -10°C to 25°C (14°F to 77°F)
- Temperature Range
- –5°C to 300°C (23°F to 572°F)
- Temperature Resolution
- 0.1°C (0.1°F)
- Thermal Sensitivity
- 150 mK (0.15°C)
- VFD
- AC V: 1000 V AC RMS, ±(1.3%+4) at 45∽65 Hz
COMMUNICATION & DATA STORAGE
- Connectivity
- Bluetooth BLE
- Image File Format
- Radiometric
- Storage
- 40,000 readings per memory set
- Storage Media
- eMMC 4GB
- Stored Image Capacity
- up to 30,000
- Video Recording
- 50 minutes maximum duration
20 seconds max duration for file transmission
USER INTERFACE
- Display
- 2.8"
- Display Brightness
- High, Medium, Low
POWER
- Auto Power Off
- For Meter: set to OFF, 2, 5, or 10 minutes
For Worklight only: set to OFF, 5, 15, or 30 minutes
- Battery
- TA04, Lithium Polymer Rechargeable, 3050 mAh. Two supplied.
- Battery Life
- Approx. 6.5 hours in IGM mode with display brightness set to medium.
Approx. 10 hours in Multimeter mode (medium brightness)
- Non_Contact Voltage Detector [NCV]
- Yes
GENERAL
- Dimensions (L x W x H)
- 20 cm × 9.6 cm × 5.6 cm (7.9 in × 3.8 in × 2.2 in)
- Included
- 1 x DM286 Industrial Thermal Imaging Multimeter
1 set of CATIV 600V Test Lead
1 set of CATIV 600V Alligator Clip
1 x Type-A to Micro-USB Cable (with Data transfer capability)
1 x K-type Thermocouple (-30°C to 260°C)
1 x Soft-sided carrying case
1 x FLIR Quick Start Guide
1 x FLIR Warranty Card
2 x TA04 Rechargeable Battery Cell
- Weight
- 569 g (1.25 lb) without battery (approx.)
- Worklights
- x1 LED
ENVIRONMENTAL & CERTIFICATIONS
- Certifications
- ETL, FCC, CE, RCM, UKCA, FDA, EN60825, EN50689
- Drop test
- 2 m (6.6 ft)
- EMC
- EN61326-1
- Emissivity Settings
- 0.10 to 1.00 (default is 0.95); select from four presets or set manually.
- IP Rating
- IP40
- Laser Pointer Power
- ≤0.39 mW
- Laser Type
- Class I (red)
- Laser Wavelength
- 640 nm to 660 nm
- Operating Altitude
- 2000 m (6560 ft)
- Operating Temp & Humidity
- -10°C to 30°C (14°F to 86°F), <85% RH
30°C to 40°C (86°F to 104°F), <75% RH
40°C to 50°C (104°F to 122°F), <45% RH
- Pollution Degree
- 2.0
- Safety
- IEC 61010-1 CAT IV - 600 V, CAT III - 1000 V
- Storage temperature and relative humidity [RH]
- -20°C to 60°C (-4°F to 140°F), 0–80% RH (without batteries)
- Warranty
- Limited 10-Year Warranty https://www.flir.com/testwarranty
ACCESSORIES
- Software
- FLIR METERLiNK® app