The low weight, small size, one-touch solution
The new Fluke 6200 and 6500 PAT testers have redefined auto test capabilities to help you increase the number of portable appliance tests performed per day. They’re designed to enable you to work faster without compromising safety – yours or your customer’s.
Low weight…
Weighing approx. 3 kg, the 6200 and 6500 are lightweight and easy to carry around when working on-site. The hard carrying case (supplied) not only offers protection during transit but also includes extra storage space for accessories and other tools.
Small size…
They’re also extremely compact, and have Fluke’s traditional ruggedness to be able to withstand working in the field. Packed with all the features you need for testing portable appliances, a Fluke PAT tester is a complete all-in-one solution.
One-touch solution…
Pre-set test routines are initiated from a single button. This not only simplifies testing but also facilitates a faster, more efficient way of working. The fully automatic 6500 also includes user-definable test routines and a QWERTY keyboard for rapid data entry.
Specifications: Fluke 6000 Series Portable Appliance Testers
Test Specifications |
|
|
The accuracy specification for the display range is defined as ± (%reading + digit counts) at 23 °C ± 5 °C, ≤ 75 % RH. Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. |
|
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997 , EN61557-4: 1997. |
|
Power-on Test |
|
The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. |
Display range: |
90 V to 264 V |
Accuracy at 50 Hz: |
± (2% + 3 counts) |
Resolution: |
0.1 V (1 V - model 6200) |
Input impedance |
> 1 MΩ // 2.2 nF |
Maximum input mains voltage: |
300 V |
|
Earth Bond Test (Rpe) |
Display range: |
0 to 19.99 Ω |
Accuracy (after Bond Test zeroing): |
± (2.5% + 4 counts) |
Resolution: |
0.01 Ω |
Test current: |
200 mA AC -0% +40% into 1.99 Ω |
|
25 A AC ± 20% into 25 mΩ at 230 V |
Open circuit voltage: |
> 4 V AC, < 24 V AC |
Bond test zeroing: |
can subtract up to 1.99 Ω |
|
Insulation Test (Riso) |
Display range: |
0 to 299 MΩ |
Accuracy: |
± (5% + 2 counts) from 0.1 to 300 MΩ |
Resolution: |
0.01 MΩ (0 to 19.99 MΩ) |
|
0.1 MΩ (20 to 199.9 MΩ) |
|
1 MΩ (200 to 299 MΩ) |
Test voltage: |
500 V DC -0% + 10% at 500 kΩ load |
Test current: |
> 1 mA at 500 kΩ load, < 15 mA at 0 Ω |
Auto discharge time: |
< 0.5 s for 1 μF |
Max. capacitive load: |
operational up to 1 μF |
|
Touch Current Test |
Display range: |
0 to 1.99 mA AC |
Accuracy: |
± (4% + 2 counts) |
Resolution: |
0.01 mA |
Internal resistance (via probe): |
2 kΩ |
Measuring method: |
probe |
|
The appliance under test is energized at mains potential. |
|
Substitute Leakage Current Test |
Display range: |
0 to 19.99 mA AC |
Accuracy: |
± (2.5% + 3 counts) |
Resolution: |
0.01 mA |
Test voltage: |
35 V AC ± 20% |
|
Load/Leakage Test: Load Current |
Display range: |
0 to 13 A |
Accuracy: |
± (4% + 2 counts) |
Resolution: |
0.1 A |
|
The appliance under test is energized at mains potential. |
|
Load/Leakage Test: Load Power |
Display range: |
0 to 999 VA |
|
1.0 kVA to 3.2 kVA |
Accuracy: |
± (5% + 3 counts) |
Resolution: |
1 VA (0 to 999 VA) |
|
0.1 kVA (1.0 kVA to 3.2 kVA) |
|
The appliance under test is energized at mains potential. |
|
Load/Leakage Test: Leakage Current |
Display range: |
0 to 19.99 mA |
Accuracy: |
± (4% + 4 counts) |
Resolution: |
0.01 mA |
|
The appliance under test is energized at mains potential. |
|
PELV Test |
Accuracy at 50 Hz: |
± (2% + 3 counts) |
Overload protection: |
300 Vrms |
Warning threshold: |
25 Vrms |
|
Environmental Specifications |
Operating Temperature |
|
Relative Humidity |
|
non condensing < 10 °C |
|
95% from 10 to 30 °C |
|
75% from 30 to 40 °C |
|
Safety Specifications |
Safety Rating |
|
Mechanical & General Specifications |
Size |
|
200 mm (L) x 275 mm (W) x 100 mm (H) |
|
Weight |
|
Power Supply |
|
V + 10 % - 15 %, 50 Hz ± 2 % |
|
Power Consumption (Tester) |
|
13 W typical (idle) |
|
60 W max. during 25A Bond Test |
|
Storage |
Temperature: |
-10 to 60 °C |
Corrosion: |
70 °C @ 95 % RH for 5 days max. |
|
Operating Altitude |
|
Sealing |
|
IP-40 (enclosure), IP-20 (connectors) |
|
EMC |
|
complies with EN61326-1, criteria B |
|
EMI Immunity |
|