021 -2216 3350
info@bapj.co.id

Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit

Update Terakhir
Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit
Negara Asal
AMERIKA
Pembelian minimum
1
Harga
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

Key features

Fluke 62 MAX+. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.

Fluke 323 True-rms Clamp Meter.Rugged. Reliable. Precise.

  • 400 A AC current measurement.
  • 600 VAC and DC voltage measurement.
  • True RMS AC voltage and current for accurate measurements on non-linear signals.
  • Resistance measurement up to 40 kΩ with continuity detection.
  • Slim, ergonomic design.
  • CAT IV 300V/CAT III 600 V safety rating.

Fluke 1AC II VoltAlert™ Voltage Detector

  • Voltbeat™ technology and continuous self-test, so always know it’s working.
  • Upon detection, tip glows and beeper sounds.
  • Voltage detection of 90 to 1000 VAC.
  • CAT IV 1000 V for added protection.

Fluke C115 Soft Case

  • Lightweight soft case to provide optimal protection and accessory storage.

Product overview: Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit

This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use the clamp meter and voltage detector to find out more about the problem

Specifications: Fluke 62 MAX+/323/1AC IR Thermometer, Clamp Meter and Voltage Detector Kit

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature range -30°C to 650°C (-22°F to 1202°F)
Accuracy ±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%) < 300 ms (95% of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Optical resolution 12:1 (calculated at 90% energy)
Display resolution 0.1°C (0.2°F)
Repeatability of readings ±0.5% of reading or < ±0.5°C (1°F), whichever is greater
Power AA battery
Battery life 8 hours with laser and backlight on
Physical Specifications
Weight 255 g (8.99 oz)
Size 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity 10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
IP rating IP 54 per IEC 60529
Drop test 3 meters
Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006
Standards and agency approval Compliance EN/IEC 61010-1: 2001
Laser safety FDA and EN 60825-1 Class II

Fluke 323 True RMS Clamp Meter

Specifications
AC current Range 400.0 A
Accuracy 2% ±5 digits
(45 Hz to 65 Hz)
2.5% ±5 digits
(65 Hz to 400 Hz)
AC voltage Range 600.0 V
Accuracy 1.5% ±5 digits
DC voltage Range 600.0 V
Accuracy 1.0% ±5 digits
Resistance Range 400.0 Ω/ 4000 Ω
Accuracy 1.0% ±5 digits
Continuity ≤ 70 Ω
AC response True-rms
Data hold Yes
Size H x W x D (mm) 207 x 75 x 34
Max wire diameter 30 mm (600 MCM)
Weight 265 g
Category rating CAT III 600 V
CAT IV 300 V
Warranty Two-year

Fluke 1AC-II VoltAlert

Specifications
Operating principle Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.
Voltage sensing ranges Nominally, 90 VAC to 1000 VAC or 200 VAC to 1000 VAC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model
Detector tip style Blade or round, depending on model
Light source One high intensity red LED
Agency approvals c CSA us, CE, C-Tick
Safety rating 1000 V, CAT IV
IP rating IP 40
Operating temperature -10°C to 50°C
Operating humidity ranges 0% to 95% (0°C to 30°C)
0% to 75% (30°C to 40°C)
0% to 45% (40°C to 55°C)
Operating altitude 3000 meters
Batteries 2 AAA alkaline batteries included
Product does not respond to random electrostatic discharge.

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?