Designed for field pressure calibration, the Fluke 700G Series Pressure Gauge Calibrators give you the performance and durability that you have come to expect in Fluke pressure calibration products while being simple and easy-to-use. Whether you’re looking to connect to either a hydraulic or pneumatic test pump this series are designed to be a complete calibration solution with:
With a standard accuracy of 0.05% of full scale and reference class gauges with accuracies of 0.04% you’re sure to find a gauge that’s the perfect fit for your application.
The Fluke 700G series gauges and pump kits are designed for the pressure testing professional working on process pressure instrumentation. The pressure ranges of the 700G series gauges cover the ranges needed for process pressure calibration needs including Gage pressures +/- 10 inH20 (+/- 25 mbar) to 10,000 psi (0-690 bar), absolute pressures from 0 to 15 psia (0-1 bar) to 0-300 psi (0-20 bar) and reference class gauges from 0 to 30 PSI (0-2 bar) to 10,000 psi (0-690 bar).
Pressure gauge calibrators are the easiest to use of all pressure calibration tools. Power them up, connect to the pressure device you want to measure and see your measurement, it’s that easy. When used with a Fluke-700PTPK pneumatic or 700HTPK hydraulic pump kit the 700G becomes a complete pressure sourcing and measurement solution. The 700PTPK2 and 700HTPK2 premium pump kits offer easy connectivity to the gauge and device under test providing “no tools required” connections.
Model | Range | Resolution | Accuracy | Burst Pressure |
---|---|---|---|---|
Fluke-700G01 | -10 to +10 inH2O -20 mbar to 20 mbar |
0.001 inH2O, 0.001 mbar |
Positive pressure ±0.1% of range, Vacuum ±0.1% of range |
3 psi, 210 mbar |
Fluke-700G02 | -1 to +1 psi, -70 mbar to 70 mbar |
0.0001 psi, 0.001 mbar |
Positive pressure ±0.1% of range, Vacuum ±0.1% of range |
5 psi, 350 mbar |
Fluke-700G04 | -14 to 15 psi, -0.97 to 1 bar |
0.001 psi, 0.0001 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
60 psi, 4 bar |
Fluke-700G05 | -14 to 30 psi, -0.97 to 2 bar |
0.001 psi, 0.0001 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
120 psi, 8 bar |
Fluke-700G06 | -12 to 100 psi, -0.83 to 6.9 bar |
0.01 psi, 0.0001 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
400 psi, 26 bar |
Fluke-700G27 | -12 to 300 psi, -0.83 to 20 bar |
0.01 psi, 0.001 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
1200 psi, 80 bar |
Fluke-700G07 | -12 to 500 psi, -0.83 to 34 bar |
0.01 psi, 0.001 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
2000 psi, 138 bar |
Fluke-700G08 | -14 to 1000 psi, -0.97 to 69 bar |
0.1 psi, 0.001 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
4000 psi, 266 bar |
Fluke-700G10 | -14 to 2000 psi, -.97 bar to 140 bar |
0.1 psi, 0.01 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
8000 psi, 550 bar |
Fluke-700G29 | -14 to 3000 psi, -0.97 to 200 bar |
0.1 psi, 0.01 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
10000 psi, 690 bar |
Fluke-700G30 | -14 to 5000 psi, -0.97 to 340 bar |
0.1 psi, 0.01 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
10000 psi, 690 bar |
Fluke-700G31 | -14 to 10000 psi, -0.97 to 690 bar |
1 psi, 0.01 bar |
Positive pressure ±0.05% FS Vacuum ±0.1% FS |
20000 psi, 1035 bar |
Fluke-700GA4 | 0 to 15 psia, 0 to 1 bar absolute |
0.001 psi, 0.0001 bar |
±0.05% of range | 60 psi, 4 bar |
Fluke-700GA5 | 0 to 30 psia 0 to 2 bar absolute |
0.001 psi, 0.0001 bar |
±0.05% of range | 120 psi, 8 bar |
Fluke-700GA6 | 0 to 100 psia, 0 to 6.9 bar absolute |
0.01 psi, 0.0001 bar |
±0.05% of range | 400 psi, 27 bar |
Fluke-700GA27 | 0 to 300 psia, 0 to 20 bar absolute |
0.01 psi, 0.001 bar |
±0.05% of range | 1200 psi, 80 bar |
Fluke-700RG05 | -14 to +30 psi, -0.97 to +2 bar |
0.001 psi, 0.0001 bar |
Positive pressure, ±0.04% of reading +.01% of range, Vacuum ±0.05% of range |
90 psi, 6 bar |
Fluke-700RG06 | -12 to 100 psi, -0.83 to 6.9 bar |
0.01 psi, 0.0001 bar |
Positive pressure, ±0.04% of reading +.01% of range, Vacuum ±0.1% of range |
400 psi, 27 bar |
Fluke-700RG07 | -12 to 500 psi, -0.83 to 34 |
0.01 psi, 0.001 bar |
Positive pressure, ±0.04% of reading +.01% of range, Vacuum ±0.1% of range |
2000 psi, 138 bar |
Fluke-700RG08 | -14 to 1000 psi, -0.97 to 69 bar |
0.1 psi, 0.001 bar |
Positive pressure, ±0.04% of reading +.01% of range, Vacuum ±0.1% of range |
4000 psi, 275 bar |
Fluke-700RG29 | -14 to 3000 psi, -0.97 to 200 bar |
0.1 psi, 0.01 bar |
Positive pressure, ±0.04% of reading +.01% of range, Vacuum ±0.1% of range |
10000 psi, 690 bar |
Fluke-700RG30 | -14 to 5000 psi, -0.97 to 340 bar |
0.1 psi, 0.01 bar |
Positive pressure, ±0.04% of reading +.01% of range, Vacuum ±0.1% of range |
15000 psi, 1035 bar |
Fluke-700RG31 | -14 to 10000 psi, -0.97 to 690 bar |
1 psi, 0.01 bar |
Positive pressure, ±0.04% of reading +.01% of range, Vacuum ±0.1% of range |
20000 psi, 1380 bar |
Media compatibility |
---|
|
Mechanical Specifications | |
---|---|
Dimensions (H x W x D) | 12.7 x 11.4 x 3.7 cm (5 x 4.5 x 1.5 in) |
Pressure connection | ¼ in NPT Male |
Housing/Weight | Cast ZNAL 0.56 kg (1.22 lb) with holster |
Display | 5-1/2 digits, 16.53 mm (0.65 in) high 20-segment bar graph, 0 to 100% |
Power | Three (3) AA alkaline batteries |
Battery life | 1,500 hours without backlight (continuous on), 2,000 hours at slow sample rate |