G GRANT RTS-8
Personal multi-channel bioreactor with non-invasive real time OD measurement
Personal multi-channel bioreactor with non-invasive real time OD measurement
About
RTS-8 is a personal bioreactor that utilizes patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the single-use falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.
Features
- Parallel cultivation of 8 tube bioreactors enables to save time and resources for bioprocess optimization
- Individually controlled bioreactor accelerates optimization process
- Possibility to cultivate microaerophilic and obligate anaerobic microorganisms (not strict anaerobic conditions)
- Reverse-Spin® mixing principle enables non-invasive biomass measurement in real time#
- Near-infrared optical system makes it possible to register cell growth kinetics
- Free of charge software for storage, demonstration and analysis of data in real time
- Compact design with low profile and small footprint for personal application
- Individual temperature control for bioprocess applications
- Active cooling for rapid temperature control, e.g. for temperature fluctuation experiments
- Task profiling for process automatization
- Cloud data storage to remotely monitor the process of cultivation while at home or using a mobile phone
Specifications
| Light source |
Laser |
| Measurement wavelength (λ) |
850 ± 15 nm |
| Measurement range |
0-100 OD600 |
| E.coli factory calibration measurement range |
0-50 OD600 |
| S.cerevisiae factory calibration measurement range |
0-75 OD600 |
| Achievable user calibration measurement error (range 0.1-6 OD600) |
± 0.3 |
| Achievable user calibration measurement error (range 6-50 OD600) |
≤ 5% |
| Achievable user calibration measurement error (range 50-75 OD600) |
≤ 10% |
| Measurement periodicity per hour |
1-60 |
| Temperature setting range |
+15°C ... +60°C |
| Temperature control range |
+15 °C below ambient ... +60 °C |
| Temperature stability |
±0.3 °C |
| Sample temperature accuracy (20°C – 37°C) |
±1 °C |
| Tube sockets |
8 |
| Sample working volume range |
3–50 ml |
| Speed control range |
150–2700 rpm |
| Reverse spin time setting range 150-250 rpm |
0 s |
| Reverse spin time setting range 250–300 rpm |
2-60 s |
| Reverse spin time setting range 300–2700 rpm |
0-60 s |
| Display |
0-60 s LCD |
| Minimum PC requirements |
Intel/AMD Processor, 1 GB RAM, Windows Vista/7/8/8.1/10/11, USB 2.0 port |
| Dimensions (W×D×H) |
350 × 690 × 300 mm |
| Weight |
20 kg |
| Nominal operating voltage |
AC 230 V, 50 Hz |
| Power consumption |
3.15 A / 500 W |
'
'
'
Catatan:
Harap Tanya stok sebelum melakukan pemesanan.
Barang akan dipacking dengan aman dan rapi.
Tidak ada complain yang diterima setelah transaksi selesai.
Tanpan video unboxing, komplain tidak akan diproses.