021 -2216 3350
info@bapj.co.id

G GRANT RTS-8 Plus

Update Terakhir
22 SEPTEMBER 2025
Negara Asal
UNITED STATES
Pembelian minimum
1
Harga
NEGO
Kategori
Minta Penawaran
Sharing:

Deskripsi produk

G GRANT RTS-8 Plus

Personal multi-channel bioreactor with non-invasive real time OD pH and pO2 measurement
Applications
  • Fermentation real time growth kinetics
  • Clone candidate screening
  • Protein expression
  • Temperature stress and fluctuation experiments Media screening and optimization
  • Growth characterization
  • Inhibition and toxicity tests
  • Strain quality control
  • Initial bioprocess optimization studies

About

Grant RTS-8 plus is a personal bioreactor that utilizes patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the single-use falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared, fluorescence and luminescence measurement systems, it is possible to register cell growth kinetics, pH and O2 non-invasively in real time. For pH and O2, innovative single-use sensor spots are used inside the tubes.

Although O2 supply is one of the major issues in the cultivation of aerobic organisms, especially in oxygen limited conditions, adequate methods for real monitoring of dissolved oxygen were missing, and sufficient O2 supply was usually assumed. Innovative non-invasive oxygen sensors integrated in falcon tubes now enable online oxygen monitoring and give new insights into metabolic activities. The pH is one of the major issues in the cultivation of cells, yeast or bacteria. Cultivation vessels which are sensor limited are widely applied in academic and industrial bioprocess development. As adequate methods for real monitoring of pH were not available, cumbersome at-line sampling was used lacking high data density and interfering with growth. Non-invasive real time pH measurement provides new insights into metabolic activity and changes in metabolic pathways

Advantages of the sensor spots

  • They are small
  • Their signal does not depend on the flow rate of the sample
  • They can be physically divided from the measuring system which allows a non-invasive measurement They can be used in disposables
  • Therefore, they are ideally suited for the examination of small sample volumes, for highly parallelized measurements in disposables, and for biotechnological applications

Specifications

Light source Laser
Measurement wavelength (λ) 850 ± 15 nm
Measurement range 0-100 OD600
E.coli factory calibration measurement range 0-50 OD600
S.cerevisiae factory calibration measurement range 0-75 OD600
Achievable user calibration measurement error (range 0.1-6 OD600) ± 0.3
Achievable user calibration measurement error (range 6-50 OD600) ≤ 5%
Achievable user calibration measurement error (range 50-75 OD600) ≤ 10%
Measurement periodicity per hour 1-60
Temperature setting range +15°C ... +60°C
Temperature control range +15 °C below ambient ... +60 °C
Temperature stability ±0.3 °C
Sample temperature accuracy (20°C – 37°C) ±1 °C
Tube sockets 8
Sample working volume range 3–50 ml
Speed control range 150–2700 rpm
Reverse spin time setting range 150-250 rpm 0 s
Reverse spin time setting range 250–300 rpm 2-60 s
Reverse spin time setting range 300–2700 rpm 0-60 s
Display 0-60 s LCD
Minimum PC requirements Intel/AMD Processor, 1 GB RAM, Windows Vista/7/8/8.1/10/11, USB 2.0 port
Dimensions (W×D×H) 350 × 690 × 300 mm
Weight 20 kg
Nominal operating voltage AC 230 V, 50 Hz
Power consumption 3.15 A / 500 W
--- ---
02 sensor +
Range 0-100%
Accuracy ±0.05% O2 at 0.2%, ±0.4% O2 at 20.9%
Drift <0.03% O2 within 30 days
Temperature range up to 40°C
Response time (t90) 6s
Storage stability 18 months
--- ---
pH sensor +
Range 4.0 - 8.5 pH
Accuracy ±0.10 pH at pH 7
Drift <0.005 pH per day
Temperature range up to 40°C
Response time (t90) <120 s
Storage stability 18 months

'

'

'

Catatan:

 

Harap Tanya stok sebelum melakukan pemesanan.

Barang akan dipacking dengan aman dan rapi.

Tidak ada complain yang diterima setelah transaksi selesai.

Tanpan video unboxing, komplain tidak akan diproses.

Terima kasih!

 

 

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?