Hach QBD1200 Laboratory TOC Analyser

Product Features

  • Want to trust your TOC results?
  • Want to lower your total cost?
  • Want to simplify your analysis process?
  • Want to save time?

 

The Hach QBD1200 TOC Analyser takes the pain out of your TOC analysis by dramatically simplifying the setup process, improving reliability of your results, and reducing overall cost of ownership

Want to trust your TOC results?

Stop throwing away your first replicate. The QBD1200 has 95% less carryover. Inconsistent results? Trust 2% standard deviation at 50 mg/L and 3% at 100 µg/L.

Want to lower your total cost?

Stop wasting money. Save 60% of your reagent costs. Say goodbye to frequent maintenance. Enjoy annual service vs. monthly.

Want to simplify your analysis process?

Tired of complicated setup? Begin testing with 90% fewer steps.

Want to save time?

Save time calibrating. Only 90 minutes for a calibration routine.

  • Accuracy:± 2 %
  • Calibration interval:1 year; time to calibrate 90 minutes
  • Calibration method:Automated routine: 18 point calibration using KHP (6 concentrations, 3 replicates each)
  • Carrier gas options:CO₂ free air, O₂, or N₂
  • Compliance certifications:ISO 8245 and DIN EN 1484;
  • USP <643> (including sterile water SST), JP-16 <2.59>, EP <2.2.44>, IP, CP, KP, US EPA 415.3 and Standard Method 5310c
  • Data logger:PDF, CSV
  • Dimensions (H x W x D):410 mm x 320 mm x 507 mm
  • Display type:10.4 inch high-res colour touch screen
  • Inorganic carbon handling:No extra inorganic Carbon removal module needed
  • Measuring range:0.4 ppb - 100 ppm
  • Overload recovery:1 measurement
  • Oxidation method:UV lamp + Hot Persulfate
  • Particle size:Up to 100 µm
  • Power requirements (Hz):47 - 63 Hz
  • Power requirements (Voltage):100/240 V AC
  • Precision:3% or 3 µg/L, whichever is greater
  • Sample homogenisation:Available with Autosampler
  • Sample to sample carryover:< 0.2%