edge® tablet style meter is a groundbreaking design that is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The smart, slim-line design means edge can be used as a hand held, wall mount or bench top meter. Combined with sophisticated technology, it delivers fast accurate results with laboratory grade precision whichever format you choose to use. Cutting-edge design, capacitive touch keypad and an intuitive user interface are just some of the attributes that make this meter stand out. DO is measured through a unique digital electrode. Connected via an easy plug-in 3.5mm connector, this smart electrode enables edge to automatically recognise and store sensor type, ID and calibration information. Programmed for basic and advanced modes, edge offers simplified screen features for routine measurements or detailed data display. It warns users if the electrode is not clean or if buffers are contaminated during calibration using the exclusive Hanna CAL-CHECK feature
Specifications:
SKU | HI2040-02 |
---|---|
Product Name | edge® Multiparameter DO Meter - HI2040 |
Quote Required | Yes |
pH Range | -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV |
pH Resolution | 0.001 pH, 0.01 pH, 0.1 mV |
pH Accuracy | ±0.002 pH, ±0.01 pH, ±0.2 mV |
pH Calibration | Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers* |
pH Temperature Compensation | ATC |
pH CAL Check (electrode diagnostics) | glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time |
EC Range | 0.00 to 29.99 μS/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity ‡ |
EC Resolution | 0.01 μS/cm, 00.1 μS/cm, 0.01 μS/cm, 0.01 mS/cm, 00.1 mS/cm |
EC Accuracy | ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater) |
EC Calibration | 1 Cell Factor calibration; 6 standards available |
TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor) |
TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
TDS Accuracy | ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) |
TDS Calibration | through EC calibration |
EC/TDS Temperature Compensation | Automatic -5 to 100 ºC (23 to 212 ºF); NoTC - can be selected to measure absolute conductivity |
Temperature Correction Coefficient | 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC |
EC to TDS Conversion Factor | 0.40 to 0.80 (default value is 0.50) |
Salinity (% NaCl) Range | 0.0 to 400.0% NaCl * |
Salinity (% NaCl) Resolution | 0.1% NaCl |
Salinity (% NaCl) Accuracy | ±1% of reading (@25ºC/77ºF) |
Salinity (% NaCl) Calibration | 1 point with HI 7037L 100% NaCl sea water standard |
Salinity (PSU) Range | 2.00 to 42.00 PSU * |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | ±1% of reading (@25ºC/77ºF) |
Salinity (PSU) Calibration | through EC calibration |
Salinity Range | 0.0 to 80.0 g/L * |
Salinity Resolution (ppt) | 0.01 g/L |
Salinity Accuracy (ppt) | ±1% of reading (@25ºC/77ºF) |
Salinity Calibration (ppt) | through EC calibration |
Dissolved Oxygen Range | 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation |
Dissolved Oxygen Resolution | 0.01 ppm, 0.1% saturation |
Dissolved Oxygen Accuracy | ±1 digit, ±1.5% of reading |
Dissolved Oxygen Calibration | one or two points at 0% (HI 7040 solution) and 100% (in air) |
Dissolved Oxygen Temperature Compensation | ATC |
Salinity Compensation | 0 to 40 g/L (with 1 g/L resolution) |
Altitude Compensation | -500 to 4000 m (with 100 m resolution) |
Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F |
Temperature Resolution | 0.1 °C, 0.1 °F |
Temperature Accuracy | ±0.5 °C, ±1.0 °F |
DO Probe | HI 764080 (included) |
Logging Type | Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots) |
Logging Memory | up to 1000 records |
Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
Power Supply | 5 VDC adapter (included) |
Environment | 0 to 50°C (32 to 122°F), RH max 95% non-condensing |
Dimensions | 202 x 140 x 12.7mm (8” x 5.5” x 0.5”) |
Weight | 250 g (8.82 oz) |
Ordering Information | HI2040 includes |
Notes | * standard Mode Only ** temperature limits will be reduced to actual probe/sensor limits. |
BOPANA ARGA PRIMA JAYA
Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16, RT.004/RW.013, Perwira, Kec. Bekasi Utara, Kota Bks, Jawa Barat 17122
Phone :+62 -21-2216-3350 & +62-21- 292531-86
Whatsapp : +62 812-8202-721 & +62 811-1871-501
Email : info@bapj.co.id || bopana.argaprima@gmail.com