HI981954 Pool Line Multiparameter Waterproof Portable pH/ORP/EC/Temperature meter is made for measuring key water quality parameters in swimming pool, hot tub, or spa water. This is an advanced meter uses a single weighted probe with multiple sensors to measure multiple parameters simultaneously and display results as pH, pH in mV, ORP, conductivity (EC), total dissolved solids (TDS), salinity, and temperature. The meter has a built-in pressure transducer for barometric pressure readings.
HI981954 Pool Line Multiparameter Waterproof Portable Temperature meter is a single tool that allows swimming pool, hot tub, and spa service technicians to measure key water quality parameters for both traditional and electrolytic saltwater pools. The auto-ranging conductivity/TDS readings can be used for low range readings to track the increase in chemicals as water evaporates from a pool and for the higher range measurement of salt required for the proper electrolysis of sodium chloride to produce chlorine.
The HI981954 can be used for both routine measurements and for process calibration in which the measurement information is then used to update the calibration of process pH, ORP and conductivity meters.
HI981954 offers many advanced features from a large dot matrix LCD that provides for an intuitive user interface in the operation of the meter, log on demand for storing readings, USB port for transferring data, and GLP data for tracking calibration data. The HI98195 has 5 sensors (pH, ORP, EC, temperature, barometric pressure) and 6 interpretative measurements (pH in mV, absolute conductivity, TDS, resistivity, salinity, seawater sigma). The HI981954 can display up to 11 parameters simultaneously on the large dot matrix LCD. The readings can be scaled in size based on the number of parameters (1 to 11) that are displayed.
Ergonomic, rugged, waterproof (IP67) design
pH CAL Check™
Five point pH calibration with seven standard buffers and five custom buffers
Quick Calibration of pH and EC sensors with a single solution
Automatic Temperature Compensation
Log-on-demand
AutoHold
GLP features
Calibration timeout to alert the user at a defined interval when the calibration has expired
Multiple language selection
200-hour battery life with battery level displayed on measurement screen
Menu driven for ease of use with virtual-key extended functionality
Contextual help at the press of a button
Backlit, graphic LCD
Meter displays a clock tag that will disappear when the reading has achieved stability
Battery Error Prevention System (BEPS)
Connectivity
Specifications :
SKU | HI981954 |
---|---|
Product Name | Pool Line Multiparameter Waterproof Portable pH/ ORP/EC/Temperature Meter - HI981954 |
Quote Required | Yes |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy | ±0.02 pH |
pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
ORP Range | ±2000.0 mV |
ORP Resolution | 0.1 mV |
ORP Accuracy | ±1.0 mV |
ORP Calibration | automatic at one custom point (relative mV) |
mV Range | ±600.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.5 mV |
EC Range | 0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm) |
EC Resolution | auto-ranging |
EC Accuracy | ±1% of reading or ±1 µS/cm whichever is greater |
EC Calibration | automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
TDS Range | 0 to 9999 ppm (mg/L); 0 to 400, 000 ppm (mg/L) (maximum value depends on TDS factor) |
TDS Resolution | manual |
TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
TDS Calibration | based on conductivity or salinity calibration |
Salinity (PSU) Range | 0.00 to 70.00 PSU |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | ±2% of reading or ±0.01 PSU whichever is greater |
Salinity (PSU) Calibration | based on conductivity calibration |
Salinity (Seawater Sigma) Range | 0.0 to 50.0 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Resolution | 0.1 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Accuracy | ±1 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Calibration | based on conductivity or salinity calibration |
Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Resistivity Resolution | dependent on resistivity reading |
Resistivity Calibration | based on conductivity calibration |
Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
Temperature Calibration | automatic at one custom point |
Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
Logging Memory | 45,000 records (continuous logging or log-on-demand of all parameters) |
Logging Interval | one second to three hours |
Connectivity | USB to PC with HI9298194 Hanna software installed |
Battery Type/Life | 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Ordering Information | HI981954 is supplied with HI7698195 multiparameter probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC/TDS/Salinity/Resistivity sensor, HI9828-20 quick calibration solution (230 mL), HI7698295 protective probe shield, HI76981952 probe maintenance kit, HI7698290 calibration beaker, HI920015 micro USB cable, 1.5V AAA batteries (4 pcs.), instrument quality certificate, probe quality certificate, and instruction manual packaged in a rugged thermoformed carrying case. |
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmospheric Pressure Accuracy | ±3 mm Hg within ±15 oC from calibration temperature |
Atmospheric Pressure Calibration | automatic at one custom point |