Product Features
The Horiba LAQUA 200 Series is a line of advanced benchtop meters designed for precise water quality analysis. These instruments are capable of measuring various parameters, including pH, ion concentration, conductivity, and dissolved oxygen. They feature a user-friendly interface with a large LCD screen, facilitating easy data interpretation. The series supports multiple calibration points to enhance measurement accuracy and offers data logging capabilities for efficient record-keeping. Additionally, the LAQUA 200 Series is compatible with a range of electrodes and accessories, making it suitable for diverse laboratory applications.
| Model | LAQUA PH210 |
|---|---|
| pH Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ± 0.01 pH |
| Calibration Points | Up to 5 (USA & NIST) / Up to 6 (DIN) |
| Buffer Options | USA, NIST, DIN |
| ORP Range | ± 2000 mV |
| Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
| Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
| Calibration Option | Yes |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
| Calibration Option | Yes |
| Memory Data | 500 |
| Auto Data Log | Yes |
| Measurement Modes | Auto Stable, Auto Hold, and Real time |
| Offset & Average Slope Display | Yes |
| Calibration Alarm | Yes (Programmable: Up to 90 days) |
| Auto Shut-Off | Yes (Programmable: Up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| Meter Inputs | BNC (for pH electrode), phono (for temperature sensor) |
| Display | Custom LCD with backlight |
| Housing | IP67 rating, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260 g (with batteries) / 216 g (without batteries) |
| Model | LAQUA PH220 |
|---|---|
| pH Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ± 0.01 pH |
| Calibration Points | Up to 5 (USA & NIST) / Up to 6 (DIN) |
| Buffer Options | USA, NIST, DIN |
| ORP Range | ± 2000 mV |
| Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
| Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
| Calibration Option | Yes |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
| Calibration Option | Yes |
| Memory Data | 1000 |
| Auto Data Log | Yes |
| Real-time Clock | Yes |
| Date & Time Stamp | Yes |
| Measurement Modes | Auto Stable, Auto Hold, and Real time |
| Offset & Average Slope Display | Yes |
| Calibration Alarm | Yes (Programmable: Up to 90 days) |
| Auto Shut-Off | Yes (Programmable: Up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| PC Communication | Yes via PC (USB) cable PN 3200779639 |
| Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
| Meter Inputs | BNC (for pH electrode), phono (for temperature sensor) |
| Meter Output | phono (for PC/printer connection) |
| Display | Custom LCD with backlight |
| Housing | IP67 rating, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260 g (with batteries) / 216 g (without batteries) |
| Model | LAQUA EC210 |
|---|---|
| Conductivity Range | ...µS/cm to 200.0 mS/cm (k=1.0) |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
| Reference Temperature | 15 to 30 °C (adjustable) |
| Temperature Coefficient | 0.00 to 10.00% (adjustable) |
| Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
| Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
| Measurement Unit | S/cm, S/m (selectable / auto-ranging) |
| TDS Range | ...ppm to 100 ppt (TDS factor=0.5) |
| Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
| Accuracy | ±0.1% full scale |
| TDS Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
| Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
| Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
| Resolution | 0.1 ppt / 0.01% |
| Accuracy | ±0.2% full scale |
| Salinity Curves | NaCl / Seawater |
| Calibration Option | Yes |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °C |
| Calibration Option | Yes |
| Memory Data | 500 |
| Auto Log Data | Yes |
| Measurement Modes | Auto Stable, Auto Hold, Real Time |
| Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| Meter Inputs | BNC (for conductivity electrode), phono (for temperature sensor) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
| Model | LAQUA EC220 |
|---|---|
| Conductivity Range | ...µS/cm to 200.0 mS/cm (k=1.0) |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
| Reference Temperature | 15 to 30 °C (adjustable) |
| Temperature Coefficient | 0.00 to 10.00% (adjustable) |
| Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
| Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
| Measurement Unit | S/cm, S/m (selectable / auto-ranging) |
| TDS Range | ...ppm to 100 ppt (TDS factor=0.5) |
| Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
| Accuracy | ±0.1% full scale |
| TDS Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
| Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
| Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
| Resolution | 0.1 ppt / 0.01% |
| Accuracy | ±0.2% full scale |
| Salinity Curves | NaCl / Seawater |
| Calibration Option | Yes |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °C |
| Calibration Option | Yes |
| Memory Data | 1000 |
| Auto Log Data | Yes |
| Real-time Clock | Yes |
| Date & Time Stamp | Yes |
| Measurement Modes | Auto Stable, Auto Hold, Real Time |
| Auto-Shut Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| Software Upgrade | Yes via PC (USB) cable PN 3200779639 |
| PC Communication | Yes via PC (USB) cable PN 3200779639 |
| Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
| Meter Inputs | BNC (for conductivity electrode), phono (for temperature sensor) |
| Meter Output | phono (for PC/printer connection) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
| Model | LAQUA DO210 |
|---|---|
| DO Range | 0.0 to 20.00 mg/L
0.0 to 200.0% |
| Resolution | 0.01 mg/L, 0.1% |
| Accuracy | ± 0.1 mg/L |
| Salinity Compensation | 0.0 to 40.0 ppt |
| Barometric Pressure Compensation | Yes |
| Temperature Compensation | Yes |
| DO Probe Type | Galvanic integrated with temperature sensor |
| Calibration Points | Up to 2 |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °C |
| Calibration Option | Yes |
| Memory Data | 500 |
| Auto Log Data | Yes |
| Measurement Modes | Auto stable, Auto hold, Real time |
| Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| Meter Inputs | BNC (for DO electrode), phono (for temperature sensor) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260 g (with batteries) / 216 g (without batteries) |
| Model | LAQUA DO220 |
|---|---|
| DO Range | 0.0 to 20.00 mg/L
0.0 to 200.0% |
| Resolution | 0.01 mg/L, 0.1% |
| Accuracy | ± 0.1 mg/L |
| Salinity Compensation | 0.0 to 40.0 ppt |
| Barometric Pressure Compensation | Yes |
| Temperature Compensation | Yes |
| DO Probe Type | Galvanic integrated with temperature sensor |
| Calibration Points | Up to 2 |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °C |
| Calibration Option | Yes |
| Memory Data | 500 |
| Auto Log Data | Yes |
| Real-time Clock | Yes |
| Date & Time Stamp | Yes |
| Measurement Modes | Auto stable, Auto hold, Real time |
| Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| PC Communication | Yes via PC (USB) cable PN 3200779639 |
| Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
| Meter Inputs | BNC (for DO electrode), phono (for temperature sensor) |
| Meter Output | phono (for PC/printer connection) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260 g (with batteries) / 216 g (without batteries) |
| Model | LAQUA PC210 |
|---|---|
| pH Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ± 0.01 pH |
| Calibration Points | Up to 5 (USA & NIST), Up to 6 (DIN) |
| Buffer Options | USA, NIST, DIN |
| ORP Range | ± 2000 mV |
| Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
| Accuracy | ± 0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
| Calibration Option | Yes |
| Conductivity Range | ...µS/cm to 200.0 mS/cm (k=1.0) |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
| Reference Temperature | 15 to 30 °C (adjustable) |
| Temperature Coefficient | 0.00 to 10.00% (adjustable) |
| Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
| Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
| Unit Setting | S/cm, S/m (Auto-ranging) |
| TDS Range | ...ppm to 100 ppt (TDS factor=0.5) |
| Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
| Accuracy | ±0.1% full scale |
| Calibration Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
| Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
| Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
| Resolution | 0.1 ppt / 0.01 % |
| Accuracy | ±0.2% full scale |
| Calibration Curves | NaCl, Seawater |
| Calibration Option | Yes |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
| Calibration Option | Yes |
| Memory Data | 500 |
| Auto Log Data | Yes |
| Measurement Modes | Auto Stable, Auto Hold, Real Time |
| Offset / Average Slope Display | Yes |
| Calibration Alarm | Yes (Programmable: up to 90 days) |
| Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| Meter Inputs | 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
| Model | LAQUA PC220 |
|---|---|
| pH Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ± 0.01 pH |
| Calibration Points | Up to 5 (USA & NIST), Up to 6 (DIN) |
| Buffer Options | USA, NIST, DIN |
| ORP Range | ± 2000 mV |
| Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
| Accuracy | ± 0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
| Calibration Option | Yes |
| Conductivity Range | ...µS/cm to 200.0 mS/cm (k=1.0) |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 mS/cm |
| Reference Temperature | 15 to 30 °C (adjustable) |
| Temperature Coefficient | 0.00 to 10.00% (adjustable) |
| Cell Constant | 0.1, 1.0, 10.0 (adjustable) |
| Calibration Points | Up to 4 (Auto) / Up to 5 (Manual) |
| Unit Setting | S/cm, S/m (Auto-ranging) |
| TDS Range | ...ppm to 100 ppt (TDS factor=0.5) |
| Resolution | 0.01 ppm (mg/L) / 0.1 ppt (g/L) |
| Accuracy | ±0.1% full scale |
| Calibration Curves | Linear (0.40 to 1.00), EN27888, 442, NaCl |
| Resistivity Range | 0.000 Ω•cm to 20.0 MΩ•cm |
| Resolution | 0.05% full scale |
| Accuracy | ±0.6% full scale; ±1.5% full scale > 18.0 MΩ•cm |
| Salinity Range | 0.0 to 100.0 ppt / 0.00 to 10.00 % |
| Resolution | 0.1 ppt / 0.01 % |
| Accuracy | ±0.2% full scale |
| Calibration Curves | NaCl, Seawater |
| Calibration Option | Yes |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
| Calibration Option | Yes |
| Memory Data | 1000 |
| Auto Log Data | Yes |
| Real-time Clock | Yes |
| Date & Time Stamp | Yes |
| Measurement Modes | Auto Stable, Auto Hold, Real Time |
| Offset / Average Slope Display | Yes |
| Calibration Alarm | Yes (Programmable: up to 90 days) |
| Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| PC Communication | Yes via PC (USB) cable PN 3200779639 |
| Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
| Meter Inputs | 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors) |
| Meter Output | phono (for PC/printer connection) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
| Model | LAQUA PD210 |
|---|---|
| pH Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ± 0.01 pH |
| Calibration Points | Up to 5 (USA & NIST) / Up to 6 (DIN) |
| Buffer Options | USA, NIST, DIN |
| ORP Range | ± 2000 mV |
| Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
| Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
| Calibration Option | Yes |
| DO Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % |
| Resolution | 0.01 mg/L or 0.1 % |
| Accuracy | ±0.1 mg/L |
| Salinity Compensation | 0.0 to 40.0 ppt |
| Barometric Pressure Compensation | Yes |
| Temperature Compensation | Yes |
| Calibration Points | Up to 2 |
| DO Probe Type | Galvanic integrated with temperature sensor |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
| Calibration Option | Yes |
| Memory Data | 500 |
| Auto Log Data | Yes |
| Measurement Modes | Auto Stable, Auto Hold, Real Time |
| Offset & Average Slope Display | Yes |
| Calibration Alarm | Yes (Programmable: up to 90 days) |
| Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| Meter Inputs | 2 x BNC (for pH and DO electrodes), 2 x phono (for temperature sensors) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
| Model | LAQUA PD220 |
|---|---|
| pH Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ± 0.01 pH |
| Calibration Points | Up to 5 (USA & NIST) / Up to 6 (DIN) |
| Buffer Options | USA, NIST, DIN |
| ORP Range | ± 2000 mV |
| Resolution | 0.1 mV (< ±1000 mV), 1 mV (≥ ±1000 mV) |
| Accuracy | ±0.3 mV (< ±1000 mV), 0.3% of reading (≥ ±1000 mV) |
| Calibration Option | Yes |
| DO Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % |
| Resolution | 0.01 mg/L or 0.1 % |
| Accuracy | ±0.1 mg/L |
| Salinity Compensation | 0.0 to 40.0 ppt |
| Barometric Pressure Compensation | Yes |
| Temperature Compensation | Yes |
| Calibration Points | Up to 2 |
| DO Probe Type | Galvanic integrated with temperature sensor |
| Temperature Range | -30.0 to 130.0 °C / -22.0 to 266.0 °F |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
| Calibration Option | Yes |
| Memory Data | 1000 |
| Auto Log Data | Yes |
| Real-time Clock | Yes |
| Date & Time Stamp | Yes |
| Measurement Modes | Auto Stable, Auto Hold, Real Time |
| Offset & Average Slope Display | Yes |
| Calibration Alarm | Yes (Programmable: up to 90 days) |
| Auto Shut-Off | Yes (Programmable: up to 30 minutes) |
| Electrode Status | Yes (On screen display) |
| Diagnostic Messages | Yes |
| PC Communication | Yes via PC (USB) cable PN 3200779639 |
| Printer Communication | Yes via Printer (RS232) cable PN 3200779638 |
| Meter Inputs | 2 x BNC (for pH and DO electrodes), 2 x phono (for temperature sensors) |
| Meter Output | phono (for PC/printer connection) |
| Display | Custom LCD with backlight |
| Housing | IP67, shock & scratch resistant, non-slip |
| Power Requirement | 2 x AA batteries |
| Battery Life | > 500 hours |
| Meter Dimensions | 160 (L) x 80 (W) x 40.60 (H) mm |
| Meter Weight | Approx. 260g (with batteries) / 216g (without batteries) |
'
'
'