JAN code : 4974425800506
Calibration : May be available depends on probes
JCSS Accredited Calibration : May be available depends on probes
SK-L400T is a 4-channel temperature logger connected with type-K thermocouple probes sold separately. Can monitor temperature of four different locations simultaneously on a large LCD. Logged data can be copied to SD card.
Photo shows an application with four probes.
■ Simultaneous measurement of four locations
Up to four type-K thermocouple probes can be connected, and the large LCD Simultaneously displays four temperatures from four locations (channels) for easy reading. ASTM (former ANSI) miniature connectors on each thermocouple enable various optional sensors to be connected.
■ Highly visible display
Measured data are displayed on a large display. Backlight makes it easy to read in dark places.
■ Logging on SD card
Measured values can be logged on SD card installed in the unit. The software "4ch Datalogger for Windows" downloadable from our website enables easy graph plotting and data analysis.
■ Alarm for upper and lower limit temperatures
Different alarm values, both upper and lower, can be set for each of four channels. If the measured value goes out of the set limit value, a buzzer sounds and an LED lamp flashes to alert.
■ Dedicated analysis software
Acquired data can be easily evaluated such as by graph plotting and integration with the software downloadable from our website.
■ Various calculation options available
Maximum, minimum, relative value, temperature difference, and offset function
■ Fourteen different logging intervals
Available logging intervals: 1, 2, 5, 10, 15, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 90 minutes.
■ Manual logging, preset logging, memo function
Equipped with manual logging, preset logging that enables you to set the time at which to start or stop logging, and a memo function for quickly logging the current measured value. Can be used for various data collection operations.
■ AC adapter sold separately
Purchase of an AC adapter is recommended for a long-term measurement.
■ Fixable on a tripod
A screw hole in the back enables the unit to be installed on a tripod.
■ Appearance of analysis software:
■ Features of analysis software
- Imports measured data from SD card and performs graph plotting.
- Calculates maximum, minimum, and average values automatically for each channel.
- Calculates integrated temperature. It helps when you analyze accumulated temperature level.
- Marker line function visualizes the points exceeding a certain temperature value or range.
- Saving the data in CSV format enables other spreadsheet software to edit it.
■ Requirements for analysis software
OS | Windows 10 (32/64 bit), Windows 8.1 (32/64 bit), Windows 8 (32/64 bit), Windows 7 (32/64 bit), Windows XP (SP3) |
Memory | 512 MB (Win XP), 2 GB (Win 7 or up) recommended |
HDD | 150 MB or more free space |
Other | CD drive |
The latest version of the software can be downloaded from our website.
Cat. No. | 8191-00 |
Product name | 4-Channel Datalogger |
Model name | SK-L400T |
No. of channels | 4 channels |
Display range | −202.0 to 1372°C |
Display accuracy | ±(0.3%rdg + 1)°C (within 23+5°C) Measurement accuracy depends on probes. +2%rdg of error is added when connected with a surface probe. |
Temperature coefficient | ± (0.01%rdg + 0.1)°C/°C (except 18 to 28°C) |
Limit of signal source resistance | 200 Ω or less Length of a thermocouple cable must be shorter than 15 m if its strand diameter is 0.32 mm, to eliminate resistance correlated with strand diameter. Ask us if the strand diameter is less than 0.32 mm. |
Resolution | 0.1°C (−202.0 to 999.9°C) 1°C (other) |
Sampling time | 1 second |
Connectable sensors | Any Type-K thermocouples connectable with ANSI thermocouple connector |
Logging interval | 14 patterns: 1, 2, 5, 10, 15, 30 sec., 1, 2, 5, 10, 15, 30, 60, or 90 min. |
Power | AA alkaline battery or AA NiMH rechargeable battery x 4, or AC adapter sold separately |
Battery life | Approx. 500 hours if used alkaline batteries, 1-minute interval logging with backlight and indication turned off in room temperature |
Material | ABS resin |
Dimensions | 158 (W) x 106 (H) x 40 (D) mm |
Weight | 420 g including batteries |
Standard accessories | SD card (8 GB) x1, AA alkaline battery x4, instruction manual |
‘
‘
‘