021 -2216 3350
info@bapj.co.id

PinAAcle 900Z Atomic Absorption Spectrometer

Update Terakhir
PinAAcle 900Z Atomic Absorption Spectrometer
Negara Asal
USA
Pembelian minimum
1
Harga
CALL FOR PRICE
Minta Penawaran
Sharing:

Deskripsi produk

PinAAcle 900Z Atomic Absorption Spectrometer

For laboratories needing a high-performance furnace-only atomic absorption (AA) spectrometer, the PinAAcle 900Z is a longitudinal Zeeman system with a true double-beam design for fast start-up and exceptional long-term stability.

 Part Number PINAACLE900Z

Overview

The PinAAcle 900Z is controlled by the new Syngistix for AA Software, a workflow-based software designed to speed and simplify the journey from sample to results across a wide range of atomic absorption techniques.

  • True double-beam design delivers fast start-up and exceptional long-term stability
  • Cutting-edge fiber optics maximize light throughput for improved detection limits
  • TubeView color furnace camera simplifies autosampler tip alignment and sample dispensing
  • Workflow-based Syngistix for AA Software is easy to learn and use, improving laboratory productivity

 

Specifications

21 CFR Part 11 Compatible Yes
Height 64.0 cm
Model Name PinAAcle 900Z
Portable No
Product Brand Name PinAAcle
Warranty 1 Year
Weight 127.0 kg
Width 95.0 cm

Application Note

Accurate Determination of Lead in Dairy Products by Graphite Furnace Atomic AbsorptionThe performance of this method was validated by assessing the Standard Reference Materials (SRMs) from the US National Institute of Standards and Technology (NIST) and China National Institute of Metrology (NIM) as well as by comparing these results with those obtained using inductively coupled plasma mass spectrometry (ICP-MS) after complete sample digestion by microwave method.

PDF 724 KB
Analysis of Lead, Cadmium, and Arsenic in Spice Mixtures 

With an inherent toxicity, a tendency to accumulate in the food chain and a particularly low removal rate through excretion, lead (Pb), cadmium (Cd) and arsenic (As) cause harm to humans even at low concentrations.

 

PDF 766 KB
Analysis of Pb, Cd and As in Tea Leaves Using Graphite Furnace Atomic Absorption SpectrophotometryFor many years, graphite furnace atomic absorption spectrophotometry (GFAAS) has been a reliable technique and the preferred method for this heavy metals analysis of tea leaves.

PDF 589 KB
Determination of As, Se and Hg in Waters by Hydride Generation/Cold Vapor Absorption SpectroscopyContamination of industrial and municipal water supplies with arsenic (As), selenium (Se), and mercury (Hg) can occur from natural deposits, industrial discharge, runoff from mining, landfill and agricultural operations.

PDF 1 MB
Determination of Toxic, Trace and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background CorrectionIngestion of trace elements from food can be linked to nutrition, disease, and physiological development. Whether they are needed for proper nutritional value or contain toxic elements, the presence of major and minor elements in food needs to be verified to help determine health effects for the consumer. Acute or chronic exposure to heavy metals can lead to damaged nervous system function and have detrimental effects on vital organs. Food safety laboratories performing these analyses are often high-throughput and require a detection tool that is efficient and cost effective.

PDF 752 KB
Determination of Various Elements at Ultra-trace Levels in Ultrapure Acids and Photoresist Stripper Solutions by Graphite Furnace Atomic Absorption 

To protect the integrity of semiconductor and electronics end-products, semiconductor researchers and developers (R&D) and manufacturing QA/QC functions face unique challenges to reduce contaminates, sometimes down to ultra-trace levels. Metal determination in the sub-ppb range are required for the analysis of complex sample matrices and corrosive acids.

To meet these requirements, high-performance analytical techniques such as inductively coupled plasma mass spectrometry (ICP-MS) are preferred for rapid multi-element analysis, however, diagnosing problems can also involve only a few elements, in which graphite furnace atomic absorption spectrometry (GFAAS) is recommended.

Learn how GFAAS can help diagnose problems in semiconductor R&D and QA/QC processes.

 

PDF 1 MB
Fast Digestion Analysis of Lead and Cadmium in Rice Using Graphite Furnace Atomic Absorption 

Lead (Pb) and cadmium (Cd) are common pollutants in grains and are extremely toxic. Pb is harmful to human organs even at trace levels, and once it accumulates in the body, it causes inhibition of hemoglobin formation and neurological disorders. Cd is even classified as human carcinogen [Group 1 - according to International Agency for Research on Cancer]. It is reported that Cd leads to severe kidney problems which can be fatal and is also associated with brittle bones and liver problems. Rice, as the most widely consumed cereal grain in Asia/China, can quickly pick up Pb and Cd from toxins, pesticides and fertilizers in the soil, thereby endangering the health of millions of people through their diet. Therefore, it is extremely important to develop a simple, reliable method to monitor the levels of Pb and Cd in rice. According to Chinese national standard GB 2715-2016 Hygienic Standard for Grain, the maximum concentrations of Pb or Cd in grains must be below 0.2 mg/kg; the allowable level in the European Union is the same [EC 1881/2006]. The official technique for the determination of heavy metals in both cases is graphite furnace atomic absorption spectroscopy (GFAAS, GB/T 5009. 12-2017, GB/T 5009-2017. 15 and EN 14083:2003). Samples can be pretreated using various methods, including microwave digestion, hot block digestion, dry ashing, and hot plate digestion. It is found that these conventional digestion procedures are always complicated and time-consuming (two-four hours or even longer). Plus, conventional sample preparation techniques require large quantities of corrosive and oxidizing reagents, increasing the chance for contamination which could lead to inaccurate results. Special PTFE vessels are needed for microwave digestion; however, reusable utensils might also cause cross contamination.

 

PDF 412 KB
Toxic Trace Metals in Edible Oils by Graphite Furnace Atomic Absorption Spectrophotometry 

Graphite furnace atomic absorption spectrophotometry (GFAAS) has been widely applied to the determination of trace elements in food due to its selectivity, simplicity, high sensitivity, and its capability for accurate determinations in a wide variety of matrices. Edible oils are generally low in trace element concentrations, however, metals such as arsenic (As), lead (Pb), cadmium (Cd), chromium (Cr), and selenium (Se) can be found and are known for their toxicities which affect the health of consumers.

 

PDF 379 KB
Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada RequirementsPrecise and accurate measurements at the regulated levels are an important factor for assuring safe drinking water. U.S. EPA Method 200.91 is the method cited by EPA, Health Canada, and the WHO for the use of graphite furnace atomic absorption spectroscopy (GFAAS). In evaluating a GFAAS system for determination of these elements, it must provide good sensitivity, low noise, limited drift, and accuracy in matrices with high salt content (hard water) that might be found in drinking waters. In this work, the PinAAcle™ 900T, with a unique optical system, is evaluated for the use of EPA Method 200.9 for As, Cd, Pb, Se, and Tl in drinking waters.

PDF 289 KB

Brochure

Comprehensive Testing Solutions for Feed Millers 

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, and it’s clear: you’re creating a complete nutritional delivery system, not just a simple mix of grains.

 

PDF 3 MB
Grain Testing Solutions Brochure 

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics.

PerkinElmer is equipped to help the grain industry in its quest to feed the world – nutritiously and economically. Our testing and analysis solutions encompass the three primary areas required for complete knowledge of grains and their derivatives – composition, functionality, and safety.

 

PDF 6 MB
Meat and Seafood Testing Solutions 

Food testing labs like yours are constantly challenged with accurately analyzing samples quickly and efficiently - all while striving to reduce costs due to market forces. Your commitment to ensuring meat and seafood are safe for consumption, as demand increases, is an uphill battle.

Our commitment to you: to provide a range of solutions across multiple technologies, products, and services that meets or exceeds the testing needs of food processors. Our solutions offer more efficiency and increased accuracy and sensitivity for better yields in real time with minimal training.

From instrumentation and software to consumables and reagents to service and support, we are dedicated to providing you with end-to-end solutions that ease your everyday challenges of automation, throughput, service, and time to results.

 

PDF 6 MB
PinAAcle 900 Series AA Spectrometers Brochure 

The PinAAcle series of atomic absorption (AA) spectrometers brings AA performance to new heights. Engineered with an array of exciting technological advances, it offers a variety of configurations and capabilities to deliver exactly the level of performance you need:

  • Flame only, furnace only, or space-saving stacked designs featuring both
  • Flame, furnace, flow injection, FIAS-furnace and mercury/hydride capabilities on a single instrument
  • Choice of Deuterium or longitudinal Zeeman background correction
  • TubeView color furnace camera simplifies autosampler tip alignment and sample dispensing
  • Syngistix for AA, a workflow-based software designed to speed and simplify the journey from sample to results

And no matter which model you select (900F, 900Z, 900H, 900T), you’ll discover an intuitive, highly efficient system capable of simplifying your journey from sample to results—even with the most difficult matrices. Experience peak performance and unmatched productivity. Step up to the PinAAcle series from PerkinElmer.

Download the brochure to learn more.

 

PDF 1 MB

Catalog

Atomic Spectroscopy 2018-2019 Consumables & Supplies CatalogWith instruments that are the industry standard worldwide, PerkinElmer accessories, consumables, methods and application support meet the most demanding requirements and are the preferred choice in thousands of laboratories globally.

PDF 8 MB

Ebook

Palm Oil Analysis. Complete lab solutions from upstream to downstream 

Quality control-monitoring and testing are important in ensuring the quality of palm oil. The quality control parameters are used to judge the quality of palm oil products and it can be monitored and tested to ensure that the palm oil is not deliberately or accidentally adulterated.

 

PDF 11 MB

Flyer

High Quality and Performance in Atomic Absorption Grain Testing Ensemble Flyer 

Consumers are exposed to low levels of heavy metals on a daily basis and long term exposure can have negative health impacts. Since the elements themselves are distributed unevenly throughout, for example, cereal grain, with the germ and the outer layers having the highest concentrations, analyzing these grains to detect low analyte levels with accuracy and controlled reproducibility is a challenge.

The atomic absorption analysis technique provides a high performance option with features like a closed-furnace design that is sealed at both ends with easily removable bayonet-mount windows. In addition, independently controlled external and internal gas streams provide maximum flexibility, tube life, and sensitivity.

Systems like the PinAAcle 900 AA spectrometer make it faster and easier to get from sample to results by reducing your grain method development time, while PerkinElmer consumables and superior services will keep your lab at peak performance.

 

PDF 1 MB

Guide

Atomic Spectroscopy, A Guide to Selecting the Appropriate Technique and System 

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available:

  • Atomic absorption (AA): flame and graphite furnace
  • Inductively coupled plasma optical emission spectroscopy (ICP-OES)
  • Inductively coupled plasma mass spectrometry (ICP-MS)

And selecting the most appropriate one is the key to achieving accurate, reliable, real-world results.

This guide provides a basic overview of the most commonly used techniques and the information necessary to help you select the one that best suits your specific needs and applications.

 

PDF 1 MB
PinAAcle 500/900 AA Spectrometers - Preparing Your LabThis document provides detailed instructions regarding the space, accessories and utilities required to operate PerkinElmer’s PinAAcle family of atomic absorption (AA) spectrometers (500 and 900 series) and other major AA accessories.

PDF 941 KB

Regulatory Compliance Certification

Product Certificate - PinAAcle 900Product Certificate for the PinAAcle 900

PDF 614 KB

Technical Note

Analytical Quality with Genuine PerkinElmer Graphite PartsThe production of high-quality graphite components for atomic absorption spectroscopy requires stringent quality control. To ensure high quality and consistency, a specific high-density base graphite material has been developed for use with PerkinElmer graphite furnace systems.

PDF 245 KB

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?