The Teledyne IR-700-CO2 is a non-intrusive “Smart” sensor designed to detect and monitor carbon dioxide gas in air using miniature non-dispersive Infrared Optical (NDIR) sensor technology. Available in a low and a high range version, ranges of detection (by volume) are 0-0.3%, 0-1%, 0-3%, 0-5% (low range version) and 0-10%, 0-25%, 0-50%, and 0-100% (high range version). The plug-in, field-replaceable detector provides a selective response to CO2 and features oversized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual-layer surge protection.
This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model IR-700-CO2 is embedded intuitive software that simplifies the operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model IR700-CO2 is equipped with standard analog 4-20mA, and Modbus™ RS-485 outputs. Additional integration options include a Remote Alarm Module (RAM) & HART. Detcon’s carbon dioxide gas sensor has an infinite shelf life and is supported by a 5-year pro-rated warranty.
Failsafe User-Friendly Interface
Environmentally Bulletproof
Modular and Serviceable
| Heading | Detail |
|---|---|
| System Specifications | Continuous diffusion/adsorption, Non-dispersive Infrared Optical (NDIR) - CO2, Sub-miniature plug-in field replaceable |
| Sensor Life | 5 years typical |
| Measurement Range (% by volume) | 0-0.3, 0-0.5, 0-1, 0-3, 0-5 (low range version), 0-10, 0-15, 0-20, 0-25, 0-50, 0-100 (high range version) |
| Accuracy/Repeatability | ±5% of range |
| Response Time | T50 < 15 seconds, T90 < 40 seconds |
| Outputs | Linear 4-20 mA DC, RS-485 MODBUS-RTU |
| Electrical Classification | Explosion proof, cCSAus, Class I, Division 1, Groups B, C, D (Tamb = -40°C to +75°C), Class I, Zone 1, Group IIB+H2, ATEX, II 2 G Ex d IIB + H2 T4 Gb (Tamb = -40°C to +70°C) |
| Ingress Protection | NEMA 4X, IP66 |
| Safety Approvals | cCSAus, ATEX, CE Marking |
| Warranty | Plug-in detector - 5 year pro-rated, Transmitter - 2 Years |
| Environmental Specifications | Operating Temperature Range: -40°F to +167°F; -40°C to +75°C, Storage Temperature Range: -40°F to +167°F; -40°C to +75°C, Operating Humidity Range: 0-100% RH non-condensing |
| Mechanical Specifications | Dimensions: 7”H x 2.2” Dia.; 178mmH x 65mm Dia. (sensor assembly only), 11”H x 6.1”W x 3.75”D; 280mmH x 155mmW x 96mmD (with junction box), Mounting holes (J-box) 5.5”; 140mm center to center, Weight: 2 lbs; 0.907kg (sensor only), 6 lbs; 2.72kg (w/aluminum j-box), 9 lbs; 4.08kg (w/stainless steel j-box) |
| Electrical Specifications | Power Input: 11-30 VDC, Power Consumption: Normal operation = 68mA (<1.7 watt), Maximum = 85mA (2 watts), Inrush Current: 0.67A @ 24V, RFI/EMI Protection: Complies with EN50270, Analog Output: Linear 4-20mA DC (1,000 ohms max loop load @ 24VDC), 0mA All Fault Diagnostics, 2mA In-Calibration, 4-20mA 0-100% full-scale, 22mA Over-range condition, Serial RS-485 Output: RS-485 Modbus™ RTU, Baud Rate: 9600 BPS (9600,N,8,1 Half Duplex), Status Indicators: 4-digit LED display with gas concentration, Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting, Faults Monitored: Loop, Input Voltage, Zero, Sensor, Processor, Memory, Calibration, Cable Requirements: Power/Analog, 3-wire shielded cable, Maximum distance is 13,300 feet with 14 AWG, Serial Output: 2-wire twisted-pair shielded cable specifically for use with RS-485 installations, Maximum distance is 4,000 feet to last sensor, I/O Protection: Over-voltage, Miswiring, EMI/RFI Immunity |
'
'
'