021 -2216 3350
info@bapj.co.id

Teledyne Meridian Hazardous Area Fixed Gas Detector

Update Terakhir
15 OKTOBER 2025
Negara Asal
UNITED STATES
Pembelian minimum
1
Harga
NEGO
Minta Penawaran
Sharing:

Deskripsi produk

Teledyne Meridian Hazardous Area Fixed Gas Detector

Teledyne Meridian Hazardous Area Fixed Gas Detector

The Teledyne Meridian is a Universal Gas Detector that utilizes a single detector head to easily accept all sensor types. Whether you need an infrared or catalytic bead sensor to detect combustible gases or an electrochemical sensor for a toxic environment, the Meridian is a great choice. There is no requirement for distinct personality boards in the gas detector or different detector heads to make the instrument behave as a combustible or toxic gas detector.

The Meridian gas detector accepts all sensor types in one detector. Simply attach the specific toxic or combustible sensor to the universal detector head and the Meridian gas detector will automatically determine the type of gas to be detected. Installation of the sensor is a simple plug-and-play action. At Teledyne Gas and Flame Detection, we are always looking to anticipate your future needs. We designed the Meridian gas detection platform to be future proof, allowing you to take advantage of new sensing technologies from Teledyne Gas and Flame Detection while maintaining ease of use and peace of mind.​​​​​​​​​​​​​​​​​​​​​

Certifications
Global Approvals IECEx, cCSAus, ATEX, INMETRO
INDUSTRY CANADA, CE, SIL-2 (Third Party
Certification by TUV-Rheinland)
Area Classification Class I Div. 1 Group ABCD, Class II Div. 1 Group EFG, Class III
Equipment Group I/II, Zone 0/20 & Zone 1/21, IIC
Environmental
Operating Temperature -40° to 75° Celsius
Humidity 5–95% RH (non condensing)
Storage Temperature -55° to 75° Celsius
Specifications
Power 2 wire, 3 wire, 4 wire
Operating Voltage 3/4 wire 10-30 VDC (24 VDC nominal)
Operating Voltage 2 wire 18-30 VDC (24 VDC nominal)
Power Consumption 2.2 - 3.2 Watts based on sensor configuration
Add 2.6 Watts to any configuration if heated display is used
Enclosure Material Copper-free aluminum, 316 stainless steel
Enclosure Ingress Protection NEMA 4X, IP66
Terminal Junction Box Material Copper-free aluminium, 316 stainless steel
Terminal Junction Box Conduit Connection 3/4" NPT (M20 adapter available)
Communication 4–20 mA, MODBUS; Optional HART
Maximum 4–20 loop load, OHMS (@24 VDC) 680 Ohms current source
680 Ohms current sink
Alarms 3 programmable alarms with set and reset (adjustable deadband); 1 fail safe system fault
Relays 4 Form C relays, rated 5 Amp at 30 VDC/240 VAC, resistive loads
Display Graphical LCD display visible in bright sunlight.
Display indicates Sensor Name, Gas Name, Full Scale of Range, Gas Concentration, Fault, Alarm Status, Trend Graph with selectable
time scale showing current reading, set points and full scale.
Display provides simple, intuitive calibration instructions and guides user through the calibration process.
Languages English, Portuguese, French, Spanish, Chinese, Russian
User Configuration Control Transmitter GUI, HART hand-held Communicator, MODBUS
User Interface Access Contro Transmitter provides controlled access to sensor range, alarm settings and other safety functions;
password protection for secure configuration control
Memory Non-volatile memory ensures configuration parameters are retained in the event of power loss
Sensor Specifications
Sensor Types Combustible: Catalytic bead
Electrochemical: Standard and Rock Solid sensors
Number of Sensors Supports up to 3 sensors per detector
Installation
Weight Aluminium enclosure: 6.5 lbs (3 kg); Stainless steel enclosure: 11 lbs (5 kg)
Wiring Detector accepts industry standard 2-wire, 3-wire or 4-wire inputs

Gases

Symbol Description
BR Bromine
Cl₂ Chlorine
ClO₂ Chlorine Dioxide
CO Carbon Monoxide Gas Detectors
Combustible % LEL Combustible Percent Lower Explosive Limit (LEL)
F₂ Fluorine
H₂ Hydrogen
H₂S Hydrogen Sulfide
HCl Hydrogen Chloride
HCN Hydrogen Cyanide
HF Hydrogen Fluoride
NH₃ Ammonia
NO₂ Nitrogen Dioxide Gas Detectors
O₂ Oxygen Gas Detectors
O₃ Ozone
SiH₄ Silane
SO₂ Sulfur Dioxide

Certifications

Certification Description
ATEX A product regulation which ensures the safety of equipment intended for use in potentially explosive atmospheres in the European Union.
Canadian Approvals: CSA (c), UL (c), FMc, ETLc A product regulation which ensures the safety of equipment intended for use in potentially explosive atmospheres in Canada.
CE indicates that a product has been assessed by the manufacturer and deemed to meet EU safety, health and environmental protection requirements.
IECEx The IECEx System is an international system for the safety of equipment installed in a potentially explosive atmosphere.
INMETRO Brazil's Instituto Nacional de Metrologia, Normalizacao e Qualidade Industrial, also known as INMETRO, is the body responsible for recognizing certification organizations, which should be responsible for certification of products for compliance and author
US Approvals: CSA (us), FM (us), ETL (us), UL (us) A product regulation which ensures the safety of equipment intended for use in potentially explosive atmospheres in the United States

'

'

'

Catatan:

 

Harap Tanya stok sebelum melakukan pemesanan.

Barang akan dipacking dengan aman dan rapi.

Tidak ada complain yang diterima setelah transaksi selesai.

Tanpan video unboxing, komplain tidak akan diproses.

Terima kasih!

 

 

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?