Teledyne Oldham OLCT 100 & OLC 100 Fixed Gas Detectors

Update Terakhir
13 OKTOBER 2025
Negara Asal
UNITED STATES
Pembelian minimum
1
Harga
NEGO
Minta Penawaran
Sharing:

Deskripsi produk

Teledyne Oldham OLCT 100 & OLC 100 Fixed Gas Detectors

Teledyne Oldham OLCT 100 & OLC 100 Fixed Gas Detectors

The Teledyne The OLC/OLCT 100 range of fixed detectors is designed to detect combustible, toxic, refrigerant or oxygen gases.

  • Designed for industrial applications
  • Available in explosion-proof or intrinsically safe versions, and stainless steel
  • New XP IR infrared sensor or catalytic sensor
  • A high-temperature version allows operation up to 200°C

This detector can incorporate a wide range of detection technologies, including catalytic oxidation, infrared, electrochemical, semiconductor and MEMS, to guarantee the best detection performance for different gases, measurement ranges and environmental conditions The stainless steel version of the OLCT 100 offers enhanced resistance to corrosive environments (marine applications, purification plants, food processing, etc.).

Available in explosion-proof or intrinsically safe versions, the OLCT 100 is ATEX certified for zone 1 (gas) and zone 21 (dust). The intrinsically safe OLCT 100 IS is certified for use in Zone 0 (gas)
and Zone 20 (dust).

With a Wheatstone bridge output (OLC 100) or 4-20mA output (OLCT 100), the Oldham OLCT 100 and OLC 100 are suitable for every application, with product versions designed specifically for catalytic, electrochemical, semiconductor, or poison control.

With the benefit of ATEX approval, the Oldham OLCT 100 and OLC 100 are available in explosion safe or intrinsically safe versions.

An infrared sensor is available in addition to this range. This sensor allows use in a much more severe types of environment, where the presence of poisons could harm the use of a catalytic sensor.

The product versions include:

  • OLCT 100 XP: Explosion-proof version and equipped with a catalytic, electrochemical or semiconductor sensor, for detection of explosive, toxic gases or oxygen.
  • OLCT 100 IS: Intrinsically safe version and equipped with an electrochemical sensor for detection of toxic gases or oxygen.
  • OLCT 100 XP IR: Explosion-proof version and equipped with an infrared sensor for detection of explosive gases or CO2.
  • OLCT 100 XP HT: High temperature explosion-proof version, for detection of explosive gases up to 200°C.

 

Model OLC 100 OLCT 100 XP OLCT 100 XP IR OLCT 100 XP OLCT 100 XP HT OLCT 100 XP OLCT 100 IS
Sensor Catalytic bead Catalytic bead Infrared Electrochemical Catalytic bead Semi-conductor Electrochemical
Material Epoxy-coated aluminium housing (Inox 316L optional).
316 stainless steel sensors
Dimensions (mm)
 (inches)
135 x 133 x 84
5.43 x 5.24 x 3.31"
135 x 133 x 84
5.43 x 5.24 x 3.31"
179 x 138 x 84
7.05 x 5.43 x 3.31"
179 x 138 x 84
7.05 x 5.43 x 3.31"
150 x 138 x 84
5.91 x 5.43 x 3.31"
179 x 138 x 84
7.05 x 5.43 x 3.31"
179 x 138 x 84
7.05 x 5.43 x 3.31"
Weight (kg) 0.95 1 1.1 1.1 1.8 1.1 1.1
Ingress Protection IP66
Cable Entry M20 or ¾ NPT
Supply Voltage only by OLDHAM
Controller
15.5 to 32 VDC 13.5 to 32 VDC 10 to 32 VDC 15.5 to 32 VDC 15.5 to 32 VDC 15.5 to 32 VDC
Average
Consumption
340 mA 110 mA 60 mA 23.5 mA 100 mA 100 mA 23.5 mA
Pressure atmospheric ± 10%
Output signal Usual source encoded from 0 to 23 mA (not isolated)
- linear 4 to 20 mA output, reserved for measurement
- 0 mA : electronic fault or no power supply
- < 1 mA: fault
- 2 mA: initialization mode
- > 23 mA: out of range
Approvals Compliant with European directive ATEX 2014/34/EU and with IECEx schedule for explosion-proof detectors.
OLC 100, OLCT 100 XP, OLCT 100 XP IR : ATEX II 2 GD / Ex d IIC T6 Gb / Ex tb IIIC T85°C Db IP66
OLCT 100 XP HT: ATEX II 2 GD / Ex d IIC T6 Gb / Ex tb IIIC T85°C Db IP66 (for the transmitter to be installed in a cold zone)
ATEX II 2 G / Ex d IIC T4..T2 Gb (for the sensor to be installed in the hot zone)
OLCT 100 IS Aluminum : ATEX II 2 GD / Ex ia IIC T4 Gb / Ex ia IIIC T135°C Db IP66
OLCT 100 IS Stainless Steel : ATEX II 1 GD / Ex ia IIC T4 Ga / Ex ia IIIC T135°C Da IP66
SIL 2 according to EN 50402 / EN 61508 for catalytic versions, O2, CO, NH3 and H2S
Metrological performances according to EN/IEC 60079-29-1
Electromagnetic compatibility according to EN 50270
Cable 3 active wires, shielded
cable
3 active wires, shielded
cable
3 active wires, shielded
cable
2 active wires, shielded
cable
3 active wires, shielded
cable
3 active wires, shielded
cable
2 active wires,
shielded cable

'

'

'

Catatan:

 

Harap Tanya stok sebelum melakukan pemesanan.

Barang akan dipacking dengan aman dan rapi.

Tidak ada complain yang diterima setelah transaksi selesai.

Tanpan video unboxing, komplain tidak akan diproses.

Terima kasih!

 

Produk Terkait

                                                                                      PT. Bopana Arga Prima Jaya

Office

Jl. Jupiter VI, Perum Bintang Metropol Blok A7 No.16 Bekasi Utara 17122 , Bekasi
Bekasi , Indonesia

Contact
021 -2216 3350
info@bapj.co.id
Share
apartmentenvelopebookmarkcarttagphone-handsetearthhistorymagnifiercross
× How can I help you?