Teledyne Oldham Simtronics GD10P Infrared Point Gas Detector
The Teledyne Oldham Simtronics GD10P Infrared Point Gas Detector (formally known as SIMRAD GD10P) has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations.
The GD10P infrared gas detectors differ from all other models because they utilise silicon-based solid-state infrared sources. The complete optomechanical design and construction are so stable that an ultra-fast speed of response can be achieved while providing unparalleled service life and detector stability, thus saving on maintenance and service costs.
Teledyne offers the longest combined detector and IR source warranty on the market.
For retrofit applications, a bridge interface is available allowing the detector to be connected directly to catalytic systems, using the existing cabling and control modules. The unit is supplied with worldwide performance and hazardous area approvals. Suitable for use in SIL 2 & SIL 3 systems. An industry standard HART® interface is used for the configuration of the optical fast response time and special fault levels as well as access to extended maintenance data.
| General | |
| Technology | IR-absorption, dual wavelength, dual path |
| IR-source | Solid state IR source |
| Gases detected | Hydrocarbons (for CO2 see separate data sheet) |
| Self-test | Continuous |
| Calibration | Factory set, no field recalibration |
| Configuration | HART protocol |
| Performance | |
| Accuracy Refers to -20°c to +45°c |
±3% FS between 0-50 % reading ±5% FS between 50-100 % reading |
| Response time | Methane T20 = 0.2 Sec T50 = 0.4 Sec T90 = 1.0 Sec Other gases T20 < 1.0 Sec T50 < 2.5 Sec T90 < 6.0 Sec |
| Output signal | |
| Standard | Current source 4 – 20 mA, max. Load Impedance 500 ohm |
| Option | Current sink 4 – 20 mA |
| HART® | Maintenance and configuration |
| Detector Faults (HART configurable) - Early clean optics - Dirty optics - Detector failure |
Pre warning (2 mA) Dirt accumulation (1 mA) Internal fault (0 mA) |
| Electrical | |
| Power supply | 24V DC (18 - 32V DC) |
| Power consumption | Approx. 3.5 W |
| Connection | 3-wire shielded cable (0.5-2.5mm²) |
| Cable entry | M20 Ex e cable gland |
| Temperature range | |
| Storage | -40°C to +70°C (-40°F to +158°F) |
| Operating | -40°C to +60°C (-40°F to +140°F) |
| Humidity (Operation) |
0- 100% RH |
| Explosion proof housing | |
| Ingress Protection | IP66/IP67 |
| Housing material | Stainless Steel SIS2343 (ASTM316) |
| Weight | Approx. 2.9 Kg (6.4 Lbs |
| Dimensions (LxWxH) | 264 X 104 x 106 (mm) 10.4 X 4.1 X 4.2 (Inches) |
| Warranty | |
| 5 years full warranty on a complete instrument 15 years warranty on the infrared sources |
|
| Approvals | |
| ATEX / IECEX / INMETRO | II 2 G / Ex db eb IIC T6 Gb |
| CSA | C22.2 No 152-M984 and ANSI 12.13.01-2000 Ex d e IIC T6 (for Canada only) Class I, Division 2, Groups A, B, C and D (USA and Canada |
| Various | SIL 2 certified (software is SIL 3), ABS, MED |
| Versions | |
| Gas | Ranges |
| Methane | 0-100%LEL, 0-100%vo |
| Propane | 0-100%LEL, 0-100%Vol |
| Other versions are available, please contact your dealer. | |
| Front cover | |
| Required, select one | |
| Weather protection | Supplied as standard |
| Sample flow housing | For sampling systems and bump test |
| Duct mount kit | For duct monitoring |
| Accessories | |
| Mosquito net | Extra insect protection |
| Sun shade | Shielding for extreme solar radiation exposure or snow deposit |
'
'
'